The
application revert from version
56.
10.0R000 to 5.
01.0R000 and previous versions is performed using EMA under the following conditions:
- The firmware is not reverted back to an earlier version because it is backward compatible with earlier versions.
- Any configurations performed after the upgrade will be lost after the Revert. Once the revert completes, the configuration rolls back to the time stamp in the 'Last Used' field.
- Once a revert is performed to a valid pre-56.0 SBC release, an upgrade to another pre-56.0 release is not supported. Upgrading to any other pre-56.0 releases requires the ConnexIP re-ISO installation. Refer to Re-Installing ConnexIP Operating System for SBC 5000 Series or Re-Installing ConnexIP Operating System for SBC 7000 Series for more information on ConnexIP re-ISO installation.
- The Revert procedure applies to upgrades only (both offline and LSWU); it does not apply to ConnexIP ISO or software installations.
Warning |
---|
title | Warning Note |
---|
This procedure is service impacting. |
...