Perform the following steps to gracefully shut down the SBC.
- Shutdown host power using BMC GUI Power Control.
- Shutdown BMC power [SSH to BMC console and execute
shutdown -h now
command]. - Unplug the various connections including the power from the system.
Remove the power supplies and any DSP cards from the chassis.
Note |
---|
DSP cards can be removed only from SBC 5x10 series chassis. |
...
Anchor |
---|
| Checking Physical Access to the Failed Chassis |
---|
| Checking Physical Access to the Failed Chassis |
---|
|
Check Physical Access to the Failed Chassis
...
Caption |
---|
0 | Figure |
---|
1 | Rear Panel LEDs for SBC 5x10 Series |
---|
|
|
noprint
...
Back to Top
Anchor |
---|
| Unpacking the Container |
---|
| Unpacking the Container |
---|
|
Unpack the Container
...
Disconnect the Rack Rear Support from the Rack Adapter Brackets by removing two Philips screws on each side of the
. Note |
---|
Do not remove screws attaching the Rack Adapter Brackets to the rack until after removing the chassis from the rack. |
Caption |
---|
0 | Figure |
---|
1 | Disconnecting Rack Adaptor Brackets |
---|
|
Image Modified |
Supporting the chassis from the bottom, remove the mounting hardware from the front rack ears. Slide the
forward off the Rack Adapter Brackets. Remove the Rack Adapter brackets from the rack by removing the four rack mounting screws, two each side. Caption |
---|
0 | Figure |
---|
1 | Mounting brackets |
---|
|
|
Anchor |
---|
| Install the New License |
---|
| Install the New License |
---|
|
Install the ...
License Bundle
Note |
---|
The new license bundle must be applied on the currently standalone active system before powering on the replacement system with your SSD hard drive |
...
- Locate the chassis grounding studs on the back of the chassis.
Attach the two hole chassis ground lug PN 300-30016 to the using two flat washers PN 510-00057, two split lock washers PN 510-00056, and two hex nuts PN 511-00046 as shown in the following figure.
Caption |
---|
0 | Figure |
---|
1 | Chassis grounding lug location |
---|
|
Image Modified |
Anchor |
---|
| Installing the Power Supplies |
---|
| Installing the Power Supplies |
---|
|
Install the Power Supplies
...
SSD Received with new Chassis:
- Connect the BMC and Management cables. For detailed information, refer to section see Plug the Cables Back section below.
- Configure the BMC address.
- Update the BMC Firmware.
Configure the Management port IP addresses.
Update the BIOS Firmware.
For more information, see section Firmware Configuration and Upgrade.
Note |
---|
The data on your SSD drive can be become corrupted if the BMC and BIOS versions do not correspond to the version. |
- Power off the chassis.
Insert the Original SSD:
- Power off the chassis.
- Dismount the SSD drive from the new chassis.
- Push your SSD hard drive into the chassis.
- Screw in the screw holding the hard drive.
- After the is rack mounted and the drive is inserted, you must attach the front bezel to the by aligning 4 ball studs located on the bezel assembly to the ball stud sockets located on the chassis. Apply equal forward pressure to the four corners of the bezel assembly until each of the four corners “click-in”.
- Connect the power again. For detailed information, refer to the section Connecting to Power and Power on the Switch.
...
Anchor |
---|
| plug the cables back |
---|
| plug the cables back |
---|
|
Plug the Cables Back
...
- Insert the end of the power cords to the at the rear of the chassis as shown in this figure.
- Connect the supplied power cords to the local AC power source.
Turn on your local AC power source.
Caption |
---|
0 | Figure |
---|
1 | Connecting the AC power supply |
---|
|
Image Modified |
Anchor |
---|
| Connecting to DC Power and Powering On |
---|
| Connecting to DC Power and Powering On |
---|
|
Connect to DC Power and Powering On
- Remove the clear plastic terminal cover and re-secure the cover once the following connections have been made, as shown in next figure.
- Connect Chassis ground to the Green cable
- Connect Return to the Black cable
- Connect -48V to the Red cable
- Connect the supplied DC power cables to the local DC power source.
Turn on your local DC power source.
Caption |
---|
0 | Figure |
---|
1 | Connecting the DC power supply |
---|
|
Image Modified |
Anchor |
---|
| Installing the DSP Cards |
---|
| Installing the DSP Cards |
---|
|
Install the DSP Cards
This is applicable for SBC 5x10 series. For more information on DSP card installation, refer to the sections SBC 5x10 DSP20 Module and SBC 5x10 DSP25 Module.
...
...
Back to Top
Anchor |
---|
| Firmware Configuration and Upgrade |
---|
| Firmware Configuration and Upgrade |
---|
|
Firmware Configuration and Upgrade
...
Note |
---|
As part of the application install, the system will reboot. After reboot, the standby system starts to sync with the active system automatically. The sync process can take approximately 30 to 40 minutes. The sync and server status can be monitored through CLI/EMA/EMS on the active system. |
Noprint |
Back to Top