hidden | true |
---|
MultiExcerptName | Summary of SBC Edge VMware Requirements |
---|
...
Server Hardware
...
- Intel Xeon processors (Nehalem micro-architecture or above)
- 24GB RAM
- 500 GB HDD
- Minimum 4 NICs, if physical NIC redundancy is not required, otherwise, 8 NICs (preferably with SR-IOV capability to support future SWe optimizations)
...
Software
...
Network Connections
...
- 1 Management port
- 1 HA port
- 2 Media ports
...
...
...
...
Excerpt |
---|
|
Server Hardware | - Intel Xeon processors (Nehalem micro-architecture or above)
- 24 GB RAM
- 500 GB HDD
- Minimum 4 NICs, if physical NIC redundancy is not required, otherwise, 8 NICs (preferably with SR-IOV capability to support future SWe optimizations)
| Software | vSphere ESXi 5.1 or above | Network Connections | - 1 Management port
- 1 HA port
- 2 Media ports
| RAID Storage Array | N/A |
|
...
...
_workflow_for_techpubs |
---|
AUTH1 | |
---|
JIRAIDAUTH | NA |
---|
REV5 | |
---|
REV6 | |
---|
REV3 | |
---|
REV1 | |
---|
|
This section describes
hardware and software requirements and recommendations.To install and configure
, make sure the Virtual Machine (VM) host meets the following recommended hardware, server platform and software requirements.
Warning |
---|
The recommended hardware and software settings are intended to ensure optimum stability and performance. If the recommended settings are not used, system may not behave as expected. |
Multiexcerpt |
---|
MultiExcerptName | SBC SWe for VMware – Server Hardware Requirements |
---|
|
SBC SWe for VMware – Server Hardware RequirementsThe following table lists the server hardware requirements: Caption |
---|
0 | Table |
---|
1 | Server Hardware Requirements |
---|
| |
Configuration | Requirement |
---|
Processor | Intel Xeon processors (Nehalem micro-architecture or above) Note |
---|
Sonus recommends using Westmere (or newer) processors for better SRTP performance. These processors have the AES-NI instruction set for performing cryptographic operations in hardware. |
| RAM | Minimum 24 GB | Hard Disk | Minimum 500 GB | Network Interface Cards (NICs) | Minimum 4 NICs, if physical NIC redundancy is not required. Otherwise, 8 NICs (preferably with SR-IOV capability to support future SWe optimizations). Note |
---|
Make sure NIC has multi-queue support which enhances network performance by allowing RX and TX queues to scale with the number of CPUs on multi-processor systems. |
Note |
---|
Only Intel I350 Ethernet adapter is supported for configuring as VMDirectPath I/O pass-through device. |
| Ports | Number of ports allowed: - 1 Management port
- 1 HA port
- 2 Media ports
|
Warning |
---|
The software only runs on platforms using Intel processors. Platforms using AMD processors are not supported. |
|
BIOS Setting Recommendations
Sonus recommends the following BIOS settings for optimum performance:
Caption |
---|
0 | Table |
---|
1 | Recommended BIOS Settings for Optimum Performance |
---|
|
BIOS Parameter | Recommended Setting | Details |
---|
Intel VT-x (Virtualization Technology) | Enabled | For hardware virtualization | Intel VT-d (Directed I/O) | Enabled | If available | Intel Hyper-Threading | Enabled | | Intel Turbo Boost | Enabled | | CPU power management | Maximum Performance | |
|
For example, the BIOS settings are shown below for HP DL 380p Gen8 servers. For BIOS settings of other servers, refer to the respective vendor website.
Caption |
---|
0 | Table |
---|
1 | BIOS Setting Recommendations for HP DL380p Gen8 Server |
---|
|
BIOS Parameter | Recommended Setting | Default Value |
---|
HP Power Profile | Maximum Performance | Balanced Power and Performance | Thermal Configuration | Maximum Cooling | Optimal Cooling | HW Prefetchers | Disabled | Enabled | Adjacent Sector Prefetcher | Disabled | Enabled | Processor Power and Utilization Monitoring | Disabled | Enabled | Memory Pre-Failure Notification | Disabled | Enabled | Memory Refresh Rate | 1x Refresh | 2x Refresh | Data Direct I/O | Enabled | Disabled | SR-IOV | Enabled | Disabled | Intel® VT-d | Enabled | Disabled |
|
...
Multiexcerpt |
---|
MultiExcerptName | SBC SWe for VMware – Software Requirements |
---|
|
SBC SWe for VMware – |
Software RequirementsThe following are the VMware ESXi |
...
...
software requirements: VMware ESXi Requirements Caption |
---|
0 | Table |
---|
1 | VMWare ESXi Requirements |
---|
| Software | Version | Tested and Qualified Version | For More Information |
---|
vSphere ESXi | 5.1 or above | - VMware 6.0 tested with VM version 11
| - Customized ESXi images for various server platforms are available on VMware and Hardware platform vendor sites.
- It ensures that all the required drivers for network and storage controllers are available to run ESXi server.
- Most of the customized ESXi images comes with customized management software to manage server running ESXi software.
- Customized ESXi images for HP ProLiant and IBM servers are available at:
| vSphere Client | 5.1 or above | | VMware Knowledge Base | vCenter Server | 5.1 or above | | vCenter Server |
|
Warning |
---|
Virtual network interfaces will not come up using VMware ESXi 5.5 Update 3. For more information, refer to 5.0.x Release Notes. |
Note |
---|
The VMware Standard License will be sufficient for SWe SBC unless the PKT interfaces for SBC SWe needs to be configured in Direct IO Pass-through mode. In that case, the Enterprise Plus version of VMware ESXi software is required. |
|
Third-Party References:
- Refer to VMware Compatibility Guide (external site) for a list of VMware supported Intel processors.
- Refer to ESXi hardware requirements to ensure the VMware supported Intel processors meet ESXi hardware requirements.
Downloading the SBC SWe Software Package
For more information, see Downloading SBC SWe Installation Files from SalesForce Portal.
Sonus Recommendations for Optimum Performance
Following are recommended VMware ESXi and
virtual machine (VM) configurations. General ESXi Recommendations
Following are recommended VMware ESXi configurations:
- Plan enough resources (RAM, CPU, NIC ports, hard disk, etc.) for all the virtual machines (VMs) to run on server platform, including resources needed by ESXi itself.
- Allocate each VM only as much virtual hardware as that VM requires. Provisioning a VM with more resources than it requires can, in some cases, reduce the performance of that VM as well as other virtual machines sharing the same host.
- Disconnect or disable any physical hardware devices (Floppy devices, Network interfaces, Storage controllers, Optical drives, USB controllers, etc.) under BIOS settings that you will not be using to free up interrupt/CPU resources.
Use virtual hardware version 8 and above while creating new VMs (available starting ESXi 5.x). This provides additional capabilities to VMs such as supporting VM with up to 1 TB RAM, up to 32 vCPUs etc.
ESXi Host Configuration ParametersUse VMware vSphere client to configure the following ESXi host configuration parameters on the Advanced Settings page (see figure below) before installing the
: Div |
---|
|
Caption |
---|
0 | Table |
---|
1 | ESXi Advanced Settings |
---|
| ESXi Parameter | ESXi 5.1 Settings | ESXi 5.5 Settings | ESXi 6.0 Settings |
---|
Recommended | Default | Recommended | Default | Recommended | Default |
---|
Cpu.CoschedCrossCall | 0 | 1 | 0 | 1 | 0 | 1 | Cpu.CreditAgePeriod | 500 | 3000 | 1000 | 1000 | 1000 | 1000 | DataMover.HardwareAcceleratedInit | 0 | 1 | 0 | 1 | 0 | 1 | DataMover.HardwareAcceleratedMove | 0 | 1 | 0 | 1 | 0 | 1 | Disk.SchedNumReqOutstanding | 256 | 32 | | | | | Irq.BestVcpuRouting | 1 | 0 | 1 | 0 | 1 | 0 | Mem.BalancePeriod | 0 | 15 | 0 | 15 |
|
| Mem.SamplePeriod | 0 | 60 | 0 | 60 |
|
| Mem.ShareScanGHz | 0 | 4 | 0 | 4 | 0 | 4 | Mem.VMOverheadGrowthLimit | 0 | 4294967295 | 0 | 4294967295 | 0 | 4294967295 | Misc.TimerMaxHardPeriod | 2000 | 100000 | 2000 | 100000 | 2000 | 100000 | Misc.TimerMinHardPeriod | 100 | 100 | | | | | Net.AllowPT | 1 | 0 | 1 | 0 | 1 | 0 | Net.MaxNetifRxQueueLen | 500 | 100 | 500 | 100 | 500 | 100 | Net.MaxNetifTxQueueLen | 1000 | 500 | 1000 | 500 | 1000 | 500 | Net.NetTxCompletionWorldlet | 0 | 1 | 0 | 1 | | | Net.NetTxWordlet | 0 | 2 | 1 | 2 | 1 | 2 | Numa.LTermFairnessInterval | 0 | 5 | 0 | 5 | 0 | 5 | Numa.MonMigEnable | 0 | 1 | 0 | 1 | 0 | 1 | Numa.PageMigEnable | 0 | 1 | 0 | 1 | 0 | 1 | Numa.PreferHT | 1 | 0 | 1 | 0 | 1 | 0 | Numa.RebalancePeriod | 60000 | 2000 | 60000 | 2000 | 60000 | 2000 | Numa.SwapInterval | 1 | 3 | 1 | 3 | 1 | 3 | Numa.SwapLoadEnable | 0 | 1 | 0 | 1 | 0 | 1 |
|
|
Caption |
---|
|
Image Modified |
VM Configuration Recommendations
Caption |
---|
0 | Table |
---|
1 | VM Configuration Recommendations |
---|
|
|
Settings | Recommended Configuration |
---|
vCPU | Minimum 4 vCPUs required. But In case where there are only four physical cores available, you must configure the VM with only 3 vCPUs. Any number of vCPUs may be configured depending upon the call capacity requirements. - Keep Resource Allocation setting marked as 'unlimited' with CPU freq. set to "physical processor CPU speed multiplied by number of vCPUs assigned to VM".
Note |
---|
3 vCPUs configuration is supported only from SBC 4.2.4 release. |
Note |
---|
VMDirectPath mode is only supported for PKT ports for vCPUs >=4. |
|
vRAM | Keep Resource Allocation setting marked as 'unlimited'. Reserve the memory based on call capacity and configuration requirements. Refer to SBC SWe Performance Metrics for supported call capacities with different configuration limits. |
Virtual Hard Disk | Set Hard Disk (virtual) size as 100 GB or more (based on requirements of retaining CDRs, logs, etc. for number of days) - Use Thick provisioning (eager zero)
- Hard disk size cannot be changed once SBC SWe software is installed
|
vNICs | Set number of virtual NICs as 4 (1-MGMT, 1-HA, 1-PKT0 and 1-PKT1). - Use only VMXNET3 driver
Always use automatic MAC address assignment option while creating vNICs. Associate each vNIC to separate vSwitches Use ESXi NIC teaming feature to achieve redundancy at physical NIC level.
|
vSwitch settings | - Use four different vSwitches for each vNICs onVM. This ensures various traffic to be physically separated on SBC.
- Use four different virtual networking labels, each with different VLANs or subnets.
- Always run active and standby VMs on different physical servers
- Disable VM logging
|
Note |
---|
Make sure the Processors, ESXi version and VM configuration (vCPUs, vRAMs, Virtual Hard Disk, vNICs, and vSwitch Settings) must be identical for SBC SWe HA pair. |
Note |
---|
Make sure that the BIOS and ESXi settings and recommendations must not be changed once it is applied on the server. |