Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Customer Replaceable Units

Back to SBC 7000 Series CRUs

Panel

In this section:

Table of Contents
maxLevel2

Tooltip
tipUse ESD protective device

Image Modified

Slots 1 through 4 of the

Spacevars
0series2
chassis contains DSP-LC (Large Capacity) cards.

  • Each DSP-LC card contains 28 DSP Devices.
  • Each DSP Device contains 8 Core Signal Processors.
  • Each Core Signal processor can handle many simultaneous media streams of processing.

The DSP-LC product code is SBC-7000-DSP-LC.

Caption
0Figure
1SBC 7000 DSP-LC

Image Modified

Parts and Tools Required

Tooltip
tipESD protective device

Image Modified

The following items are needed to replace a DSP-LC card:

  • Electrostatic discharge (ESD) strap
  • Replacement DSP-LC
  • A #2 Phillips-head screwdriver

Include Page
ESD_wriststrap_7K
ESD_wriststrap_7K

Replacing the DSP-LC Card

To replace a DSP-LC card:

  1. Disable the DSP-LC card via EMA GUI (All > System >Daughter Board Admin > State (Disabled)).

    Note

    Removing a disabled DSP card does not bring down the rest of the node (hot swappable).
    Removing an enabled DSP card is a hot pluggable action (the node restarts, which means that it stops providing service; this will cause a switchover to a HA peer, if present).

  2. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis (see Connecting Electrostatic Discharge Wrist Strap on SBC 7000 for details).
  3. Unscrew the thumb screws using #2 Phillips-head screwdriver, open the release levers on each side and pull the DSP-LC card.

    Caption
    0Figure
    1SBC 7000 DSP-LC card pulled out

    Image Modified

  4. To replace, insert the new DSP-LC card to the correct slot and push it completely.
  5. Close the release levers.
  6. Tighten the thumb screws using #2 Phillips-head screwdriver.
  7. Enable the DSP-LC card via EMA GUI (All > System >Daughter Board Admin > State (Enabled)).

Field Programmable Gate Array

The DSP-LC module includes a Field-Programmable Gate Array (FPGA) that may occasionally require reprogramming. Generally, reprogramming is fully autonomous and occurs during the application start process. If the FPGA update is required, expect an additional 1-2 minutes added per DSP-LC card present to the length of a normal application start process. For some older versions of the FPGA image, reprogramming requires user intervention.

Log messages pertaining to FPGA reprogramming are stored in the following files:

  • sbx_start.log_<timestamp> file located in /var/log/sonus/sbx/openclovis directory. This file contains all logs related to system startup as well as a log of other scripts that call this FPGA reprogramming utility.
  • /var/log/messages file.

If the following error is logged, refer to the Method Of Procedure SBC 7000 DSP-LC FPGA Upgrade  to update the DSP-LC card.:

Code Block
Dec 26 18:10:36  /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]:
Dec 26 18:10:36  /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]:  ERROR - DSP-LC FPGA Version does NOT support Host programming
Dec 26 18:10:36  /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]:         Current Revision: 0x00000014
Dec 26 18:10:36  /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]:         Minimum Revision: 0x00000015
Dec 26 18:10:36  /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]: 
Dec 26 18:10:36  /opt/sonus/sbx/scripts/fpgaUtil.pl[26697]:

CRU Storage

Tooltip
tipESD protective device

Image Modified

All

Spacevars
0series2
CRUs are shipped in electrostatic discharge (ESD) bags and must be handled by using appropriate ESD precautions. The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

Include Page
ESD_footnote
ESD_footnote

Pagebreak