Accomplish the following steps to switch out of the GRHA mode:
Stop the standby SBC application. On the SBC main screen, navigate to Administration > System Administration > Platform Management. The Platform and SBC Application Controls window is displayed. To stop the application, click Stop SBC Application in the status panel.
Caption | ||||
---|---|---|---|---|
| ||||
Note |
---|
The services on standby SBC server must be stopped before switching to out of the GRHA mode since the switch to out of the GRHA mode causes a temporary HA link outage. The script will verify the state of the servers and make the necessary changes. |
On the standby server, execute the following command:
To set bond monitoring type to direct-connect
and leader election algorithm type to standard
:
Code Block |
---|
> request system admin sbx2 setHaConfig bondMonitoring direct-connect leaderElection standard |
On the active server, execute the following command:
To set bond monitoring type to direct-connect
and leader election algorithm type to standard
:
Code Block | ||
---|---|---|
| ||
> request system admin sbx1 setHaConfig bondMonitoring direct-connect leaderElection standard |
Start the standby server. Log on to SBC application in EMA Platform Mode.
Caption | ||||
---|---|---|---|---|
| ||||
Note |
---|
The standby server comes up and reconnects as standby without the GRHA mode enabled on both the machines. |
...