Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1
REV5
REV6
REV3
REV1

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Customer Replaceable Units

Back to SBC 5400 CRUs

Panel

In this section:

Table of Contents
maxLevel3

Warning

Sonus-provided SFP modules must be used to guarantee proper operation of the external ports. Failure to follow this recommendation may cause permanent damage to the system.

Tooltip
tipUse ESD protective device

Image Modified

...

1 Gb SFP Parts

The 

Spacevars
0model5
supports the following Small Form-factor Pluggable (SFP) transceivers in all Management, Media, and HA ports. SFPs are Customer Replaceable Units (CRUs).

Transceiver TypeOrder CodeProduct CodeDescription
Single-mode fiberSBC-SFPSM-1GSBC-5400-SFPSMGIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI
Multi-mode fiberSBC-SFPMM-1GSBC-5400-SFPMMGIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
CopperSBC-SFPCOPPER-1GSBC-5400-SFPCOPPERGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)

...

10 Gb SFP Parts

Optionally, Pkt0 can be used as a single

...

10 Gb port, with the remaining MEDIA ports empty. The parts for the

...

10 Gb SFPs are:

Transceiver TypeOrder CodeProduct CodeDescription
Single-mode fiberSBC-SFPSM-10GSBC-5400-SFPSM10.3GB/S, SINGLE MODE, FIBER OPTIC XCVR, LC, SFP, 10KM 1310NM, DM
Multi-mode fiberSBC-SFPMM-10GSBC-5400-SFPMM10.3GB/S, MULTI-MODE, FIBER OPTIC XCVR, LC, SFP, 300M 850NM, DMI

To replace SFPs, use the procedures from the section Replacing the SFP.

Caption
0Figure
1SFP Ports

Image Modified

Parts and Tools Required

  • Electrostatic discharge (ESD) strap
  • Replacement SFP transceivers.
Note

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit.

...

Refer to Connecting ESD Wrist Strap to install it.

Anchor
ReplacingSFP
ReplacingSFP
Replacing the SFP

Perform the following procedure to replace the SFP:

  1. Attach an ESD wrist strap using the ESD grounding point on the rear panel of the chassis (

...

  1. refer to Connecting ESD Wrist Strap for details).
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Pkt0/1/2/3) and HA ports (HA 0-1).

  3. Disengage the SFP transceiver from

    Spacevars
    0model5
    . The method used to disengage the SFP transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards, as shown below.

     

    Caption
    0Figure
    1Removing SFP

    Image Modified

  4. Insert the Sonus-approved SFP transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality using the application.

CRU Storage

Tooltip
tipESD protective device

Image Modified

All 

Spacevars
0model5
CRUs are shipped in electrostatic discharge bags and should be handled using appropriate ESD precautions.

The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

Include Page
ESD_footnote
ESD_footnote