tipUse ESD protective device

1Gb SFP Parts

The 

Spacevars
0model5
supports the following Small Form-factor Pluggable (SFP) transceivers in all Management, Media, and HA ports. SFPs are Customer Replaceable Units (CRUs).

Transceiver TypeOrder CodeProduct CodeDescription
Single-mode fiberSBC-SFPSM-1GSBC-5400-SFPSMGIG-E, SINGLE MODE, FIBER OPTIC TRANSCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 10KM 1310NM, DMI
Multi-mode fiberSBC-SFPMM-1GSBC-5400-SFPMMGIG-E, MULTIMODE, FIBER OPTIC TRANCEIVER MODULE, LC, SMALL FORM PLUGGABLE (SFP), 300M
CopperSBC-SFPCOPPER-1GSBC-5400-SFPCOPPERGIGE, 1000 BASE-T SMALL FROM PLUGGABLE (SFP)

10Gb SFP Parts

Optionally, Pkt0 can be used as a single 10Gb port, with the remaining MEDIA ports empty. The parts for the 10Gb SFPs are:

...

To replace SFPs, use the procedures from the section Replacing the SFP.

Caption
0Figure
1SFP Ports

Parts and Tools Required

  • Electrostatic discharge (ESD) strap
  • Replacement SFP transceivers.
Note

To prevent damage from electrostatic discharge, an ESD strap is provided in the accessory kit. See Connecting ESD Wrist Strap to install it.

Anchor
ReplacingSFP
ReplacingSFP
Replacing the SFP

Perform the following procedure to replace the SFP:

  1. Attach an ESD wrist strap using the ESD grounding point on the rear panel of the chassis (see Connecting ESD Wrist Strap for details).
  2. Disconnect the fiber optic and/or Cat 5 cables, as appropriate, from media ports (Pkt0/1/2/3) and HA ports (HA 0-1).

  3. Disengage the SFP transceiver from

    Spacevars
    0model5
    . The method used to disengage the SFP transceiver will vary according to the manufacturer. For example, hold the wire latch and move it downwards to the horizontal position and pull it outwards, as shown below.

     

    Caption
    0Figure
    1Removing SFP

  4. Insert the Sonus-approved SFP transceiver into the desired socket and ensure that the latch mechanism engages.

  5. Reconnect the fiber optic and/or Cat 5 cables, as appropriate, to media and HA ports.
  6. Verify LEDs above the part are flashing indicating link status and data activity.
  7. Verify port functionality using the application.

CRU Storage