To install and configure
, make sure the Virtual Machine (VM) host meets the following recommended hardware, server platform and software requirements
:.
Warning |
---|
The recommended hardware and software settings are intended to ensure optimum stability and performance. If the recommended settings are not used, system may not behave as expected. |
Server Hardware Requirements
Following The following table lists the server hardware requirements:
...
Configuration | Requirement |
---|
Processor | Intel Xeon processors (Nehalem micro-architecture or above) Note |
---|
It is recommended to use Sonus recommends using Westmere (or newer) processors for better SRTP performance. These processors have the AES-NI instruction set for performing cryptographic operations in hardware. |
|
RAM | Minimum 24 GB |
Hard Disk | Minimum 500 GB |
Network Interface Cards (NICs) | Minimum 4 NICs, if physical NIC redundancy is not required. Otherwise, 8 NICs (preferably with SR-IOV capability to support future SWe optimizations). Note |
---|
Make sure NIC has multi-queue support which enhances network performance by allowing RX and TX queues to scale with the number of CPUs on multi-processor systems. |
Note |
---|
Only Intel I350 Ethernet adapter is supported for configuring as VMDirectPath I/O pass-through device. |
|
Ports | Number of ports allowed: - 1 Management port
- 1 HA port
- 2 Media ports
|
...
For example, the BIOS settings are shown below for HP DL 380p Gen8 servers. For BIOS settings of other servers, refer to the respective vendor website.
Caption |
---|
0 | Table |
---|
1 | BIOS Setting Recommendations for HP DL380p Gen8 Server |
---|
|
BIOS Parameter | Recommended Setting | Default Value |
---|
HP Power Profile | Maximum Performance | Balanced Power and Performance | Thermal Configuration | Maximum Cooling | Optimal Cooling | HW Prefetchers | Disabled | Enabled | Adjacent Sector Prefetcher | Disabled | Enabled | Processor Power and Utilization Monitoring | Disabled | Enabled | Memory Pre-Failure Notification | Disabled | Enabled | Memory Refresh Rate | 1x Refresh | 2x Refresh | Data Direct I/O | Enabled | Disabled | SR-IOV | Enabled | Disabled | Intel® VT-d | Enabled | Disabled |
|
...
Settings | Recommended Configuration |
---|
vCPU | Minimum 4 vCPUs required. But In case where there are only four physical cores available, you must configure the VM with only 3 vCPUs. Any number of vCPUs may be configured depending upon the call capacity requirements. - Keep Resource Allocation setting marked as 'unlimited' with CPU freq. set to "physical processor CPU speed multiplied by number of vCPUs assigned to VM".
Note |
---|
3 vCPUs configuration is supported only from SBC 4.2.4 release. |
Note |
---|
VMDirectPath mode is only supported for PKT ports for vCPUs >=4. |
|
vRAM | Keep Resource Allocation setting marked as 'unlimited'. Reserve the memory based on the VM capacity requirement. For capacity and performance related information, see VMware Hypervisorcall capacity and configuration requirements. Refer to benchmarking data for supported call capacities with different configuration limits. |
Virtual Hard Disk | Set Hard Disk (virtual) size as 100 GB or more (based on requirements of retaining CDRs, logs, etc. for number of days) - Use Thick provisioning (eager zero)
- Hard disk size cannot be changed once SBC SWe software is installed
|
vNICs | Set number of virtual NICs as 4 (1-MGMT, 1-HA, 1-PKT0 and 1-PKT1). - Use only VMXNET3 driver
Always use automatic MAC address assignment option while creating vNICs. Associate each vNIC to separate vSwitches Use ESXi NIC teaming feature to achieve redundancy at physical NIC level.
|
vSwitch settings | - Use four different vSwitches for each vNICs onVM. This ensures various traffic to be physically separated on SBC.
- Use four different virtual networking labels, each with different VLANs or subnets.
- Always run active and standby VMs on different physical servers
- Disable VM logging
|
...