  1. Enter "https://169.254.77.1" into a supported browser (Firefox or IE) to connect to the BMC GUI.

    Note
    The SBC 5400 is delivered with sample self-signed X.509 certificates. Please be aware that even though these sample certificates will allow you to use HTTPS to access the SBC 5400 from BMC and EMA interfaces, using this protocol with the sample certificates is not a truly secure access method. If your organization requires a more secure access, see Generating PKI Certificates.
  2. Login to the 

    Spacevars
    0model5
    BMC GUI.

    At the prompt, enter:

    Code Block
    languagenone
    Username: root
    Password: superuser 

    The

    Spacevars
    0model5
    BMC main screen is displayed.

     

  3. Click Configuration > Network tab.

    Caption
    0Figure
    1BMC Configuration Path


    The Network Settings screen is displayed.

    Caption
    0Figure
    1BMC Network Settings Screen

  4. Configure the IPv4 Address, Subnet Mask and Default Gateway network settings. Else, select Use DHCP to obtain the IPv4 configuration details automatically.
  5. Select the Enable JViewer, Enable SSH and Enable IPMI options under Security depending upon your requirements.

    Note

    Enable IPMI is a service impacting operation. This reboots both the BMC and the host server. The changes to any of the three security items does not occur until the Save button is clicked.

    Include Page
    IPMI_Security_Vulnerability
    IPMI_Security_Vulnerability

  6. Click Save.

    Caption
    0Figure
    1Configuring BMC Network

    Caption
    0Figure
    1Rebooting BMC for Enabling IPMI


    Click Ok to reboot the BMC.

  7. Once you click Save, the following warning message appears:

    Caption
    0Figure
    1BMC Network Configuration Warning Message

  8. Click OK to proceed. A pop up window appears stating that the security configuration is successfully completed.

    Caption
    0Figure
    1Successful Configuration Message

  9. Click OK to complete the process.
  10. Disconnect the PC/Laptop from the FSP.
  11. Connect the FSP of 

    Spacevars
    0model5
    to allow remote access of the BMC.

    Caption
    0Figure
    1Field Service Port

...