To configure the SBC to use the appropriate interface for handling ENUM Queriesqueries, sequentially perform the following configuration steps: For using the Signaling Packet Interface: - Add the intended Static Route to the ENUM server. For further details on creating a Static Route, refer to System Provisioning - Static Route.
- Set the Type parameter of the Lsresd Lwresd Profile as IP. See the To Edit Lwresd Profile section in this page.
- Add an IP Access Control List (ACL) rule to get the response of the ENUM Queries. For further details on adding ACL rules, refer to Ip Access Control List - Rule.
For using the Management Signaling Interface (default): - Delete Add the intended Static Route (if any) from the list of Static Routes added to the ENUM Serverserver. For further information details on deletion of creating a Static RoutesRoute, refer to System Provisioning - Static Route.Add the intended Static Route to the ENUM server. For further details on creating a Static Route
- Set the Type parameter of the Lwresd Profile as Signaling IP. See the To Edit Lwresd Profile section in this page.
For using the Management Interface (default): - Delete the Static Route (if any) from the list of Static Routes added to the ENUM Server. For further information on deletion of Static Routes, refer to System Provisioning - Static Route.
- Set the
Type parameter of the Lwresd Profile as Mgmt . See the To Edit Lwresd Profile section in this page. - Add an IP Access Control List (ACL) rule to get the response of the ENUM Queries. For further details on adding ACL rules, refer to Ip Access Control List - Rule.
|