maxLevel2

...

  • Clear current outstanding alarms or clear all alarms from the history buffer.

  • Set alarm's acknowledge state and/or add a comment to an outstanding alarm.

Command Syntax

The command syntax to clear or set alarms is listed below.

Code Block
languagenone
> request alarms 
	clear
		current
			alarmId <integer>
			deleteMatchingAlarms <no | yes>
		history
	current
		comment alarm
			id <integer>
			text <operator comment>
		state alarm
			acknowledgeState <acknowledge | unAcknowledge>
			id <integer>

Command Parameters

Caption
0Table
1'request alarms' Parameters
ParameterDescriptions
request alarms clear

Use this command to either clear current outstanding alarms or clear all alarms from history buffer.

  • current – Use this parameter to clear all current/outstanding alarm(s). To clear a specific alarm, include the alarmId option below.
    • alarmId – Unique alarm identifier.
    • deleteMatchingAlarms– Set this flag to "yes" to delete all alarms matching the alarm Id.
      • no
      • yes
  • history – Clear all alarms from the history buffer.
request alarms current

Use this commend to either set alarm's acknowledge state and/or add a comment to an outstanding alarm.

  • comment alarm – Add a comment to an outstanding alarm.
    • id <integer> – Unique alarm identifier.
    • text <operator comment> – Operator comments
  • state alarm – Set operator state of a specific alarm using alarm Id.
    • acknowledgeState – The current operator state of the outstanding alarm.  
      • acknowledge
      • unAcknowledge (default)
    • id <integer> – Unique alarm identifier.

Command Example

To clear all current/outstanding alarm(s):

...