 CRUs are described in this section

...

:

Children Display

...

style
In spacevars
h5

 

0series2
platform, system behavior in case of component replacement and insertion is a combined function of both the hardware and the software. The component replacement behavior of 
Spacevars
0series2
platform is:

Hot Swappable Behavior: A hot swappable component can be removed and replaced without any involvement on the part of the user. The appropriate alarms will be raised and automatically cleared by the system. The node continues to deliver service if it is active or provide protection if it is standby. The hot swappable behavior provides a simple, higher-performance, and more maintainable method of achieving autonomic behavior.

Excerpt Include
SBC 5000 Series CRUs
SBC 5000 Series CRUs
nopaneltrue

 Hot Pluggable Behavior: A hot pluggable component can be removed or replaced when the system is in running condition. The node stops providing the service. Depending on the removed component or device, the BMC may immediately power down the remaining components. Removing a hot pluggable component must not damage the component or the any other component of the system.

Caption
0Table
1SBC 7000 Component Replacement Behavior
3SBC 7000 Component Replacement BehaviorComponent replacement behavior
Component NameComponent Replacement Behavior
AC/DC power supplyHot Swappable
Fan assemblyHot Swappable
Air FiltersHot Swappable
Solid State DrivesHot Pluggable
SFP and SFP+Hot Swappable
BezelHot Swappable
BMC system control card (SCC7000)Non-Hot Pluggable
CSC7000 (Core Server Card)Hot Pluggable
SBC 7000 DSP-LC (Large Capacity)Hot Pluggable

...