The SBC application revert from version 5.

...

1.0R000 to

...

5.

...

0.0R000 and previous versions is performed using EMA

...

under the following conditions:

  • The firmware is not reverted back to an earlier version because it is backward compatible with earlier SBC versions.
  • Any configurations performed after the upgrade will be lost after the Revert. Once the revert completes, the configuration rolls back to the time stamp in the 'Last Used' field.
Note

Firmware is not reverted back to earlier version as it is backward compatible with earlier SBC version.

Note

All configurations performed after the upgrade will be lost on initiating the Revert. When the revert is complete, the configuration will rollback to the timeline mentioned in 'Last Used' field.

...

  • The Revert procedure applies to SBC Upgrades only (both offline and LSWU); it does not apply to ConnexIP ISO or SBC installations.

 

Warning
titleWarning

This procedure is service impacting.

...

Note

The Revert

...

procedure is not supported on SBC 5100

...

or SBC SWe

...

.

Note

The Revert procedure reverts only the SBC application and not the ePSX application.

The following procedure describes the 

Spacevars
0series4
application revert using the EMA:

  1. Launch the EMA. See Logging On to EMA in Platform Mode for guidance.

    Note

    You may launch the EMA in either the active or standby server.

    Caption
    0Figure
    1Logging On to EMA Platform

    Image Modified

  2. Verify the versions in Monitoring > Dashboard > System and Software Info.

    Caption
    0Figure
    1New Application and OS Version

    Image Modified

  3. Navigate to Administration > System Administration screen.

    Caption
    0Figure
    1System Administration Screen

    Image Modified

  4. Click Revert Software Version.
    The Revert Software Version screen is shown. This displays the System or Partition for the current version and the older version.

    Caption
    0Figure
    1Revert Software Screen

    Image Modified

  5. Click on Image Modified to start the revert.
  6. A confirmation message appears on the screen. Click Ok to proceed.

    Caption
    0Figure
    1Confirmation of Revert Operation

    Image Modified

    Note

    The Revert Software application simultaneously reverts both the Active (WFDSBC01a) and Standby (WFDSBC01b) server. On continuing with revert, the upgraded server(s) will reboot and come up with earlier release. During this process browser session will be lost and need to re-login.


    The Revert Software starts and changes the boot version to earlier version in both the active and standby server. For example, in this case it is 04.02.03R000 version. You can see the revert status in the Log section.

    Caption
    0Figure
    1Revert Logs

    Image Modified

    Caption
    0Figure
    1Continuing Revert Operation

    Image Modified

  7. Once you see Rebooting message in the logs, log out from the EMA.

    Caption
    0Figure
    1Rebooting SBC Platform

    Image Modified

    Note

    The revert operation takes

...

  1. approximately 15 to 20 minutes to complete.

  2. Launch the Platform Manager using the default credentials.

    Note

    Beginning with 5.0 release, the Platform Manager is integrated into the EMA and hereafter referred to as EMA Platform Mode. So once it is reverted back to 3.x/4.x release, you may only use Platform Manager tool for further upgrades.

  3. Verify the revert software versions in Platform > Software Versions.

    Caption
    0Figure
    1Active Server Revert Status

    Image Modified

    Caption
    0Figure
    1Standby Server Revert Status

    Image Modified

    Note

    The roles of Active and Standby server may interchange depends upon the server, which is booting first. In this case, WFDSBC01b completed the rebooting first and became active.

     

...

  1.  

Pagebreak

...