Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Type: Major

Description

This alarm indicates that the STUN check timer is expired and call is disconnected when using local IPv6 address.

Repetition

None

Event Codes

sonusAlarmNodeID
sonusAlarmLevel
sonusAlarmSequenceId
sonusAlarmTime
sonusAlarmDescription
sonusSipIceGcid
sonusSipIceLocalIpV6Address
sonusSipIceLocalPort

sonusSipIceFailReason(string)

Instance Fields

sonusSipIceGcid
sonusSipIceLocalIpV6Address
sonusSipIceLocalPort

sonusSipIceFailReason(string)

Action

Check why the remote end is not able to complete STUN/ICE signaling correctly.

Impact

On expiry of STUN check timer, call is disconnected.

Clearing

Manual