Add_workflow_for_techpubs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||
---|---|---|---|---|
In this section:
|
Warning | ||
---|---|---|
| ||
The VLAN tagged SRIOV packet interfaces are unable to ping endpoint PKTART/Gateway IPs in the VMware platform. |
Info | ||
---|---|---|
| ||
Ensure that the SR-IOV is enabled on the BIOS settings of the host by logging through iLO console. |
Info | ||
---|---|---|
| ||
The SR- IOV is a licensed feature on the VMware and the "VMware vSphere Enterprise Plus" license must be procured to enable SR-IOV Support on the ESXi. |
Install SR-IOV supported two 10 Gigabit PCI cards.
One virtual interface for Management Port
One virtual interface for HA Port
Two virtual interfaces for SR-IOV Ports
Info | ||
---|---|---|
| ||
It is recommended to configure all four ports with different IP addresses in four different networks. For example:
|
Perform the following steps:
Log on to VMware ESXi GUI as the root user.
Caption | ||||
---|---|---|---|---|
| ||||
To check the status of the SR-IOV cards:
Navigate to Host > Manage.
Select the tab Hardware.
Ensure both the SR-IOV cards are in disabled state or the Passthrou Passthrough must be in disabled state.
Caption | ||||
---|---|---|---|---|
| ||||
If the SR-IOV cards are not disabled, they must be disabled by performing following:
Enable SSH. To enable SSH,
Navigate to Host and select the tab Actions.
From the drop-down list, select the option Services. Click Enable Secure Shell (SSH) and Enable console shell.
Caption | ||||
---|---|---|---|---|
| ||||
Check the name of the NIC cards. To check the name of the NIC cards,
Log on to CLI as root.
Execute the following command:
Code Block | ||
---|---|---|
| ||
lspci|grep X540 |
The following is the sample display output:
Code Block |
---|
0000:0b:00.0 Network controller: Intel(R) Ethernet Controller X540-AT2 [vmnic8] 0000:0b:00.1 Network controller: Intel(R) Ethernet Controller X540-AT2 [vmnic9] |
Open the esx.conf
file and find the PCI ID associated with the NIC card.
Change the owner of the PCI ID from passthru
passthrough
to vmkernel
.
Execute the following command:
Code Block |
---|
vi /etc/vmware/esx.conf |
The following is the sample display output:
Code Block |
---|
/system/uuid = "5a33649d-c9db-e792-c676-5cb9018acc24" /system/uservars/psa/defaultLunMasksInstalled = "1" /system/uservars/corestorage/Filter/DefaultVMWRulesLoaded = "1" /system/uservars/corestorage/VAAI/DefaultVMWRulesLoaded = "1" /system/uservars/host-acceptance-level = "partner" /resourceGroups/version = "6.5.0" /adv/Misc/HostIPAddr = "10.54.12.81" /adv/Misc/DiskDumpSlotSize = "2560" /adv/Misc/HostName = "hpg9-9" /adv/Net/ManagementIface = "vmk0" /adv/Net/ManagementAddr = "10.54.12.81" /adv/UserMem/UserMemASRandomSeed = "1418738923" /adv/UserVars/HostClientCEIPOptIn = "1" /device/00000:005:00.0/vmkname = "vmhba1" /device/00000:002:00.0/vmkname = "vmnic0" /device/00000:002:00.2/vmkname = "vmnic2" /device/00000:003:00.0/vmkname = "vmhba0" /device/00000:002:00.1/vmkname = "vmnic1" /device/00000:011:00.1/owner = "vmkernel" /device/00000:011:00.1/device = "1528" /device/00000:011:00.1/vendor = "8086" /device/00000:011:00.1/vmkname = "vmnic9" /device/00000:004:00.2/vmkname = "vmnic6" /device/00000:004:00.1/vmkname = "vmnic5" /device/00000:002:00.3/vmkname = "vmnic3" /device/00000:004:00.0/vmkname = "vmnic4" /device/00000:005:00.1/vmkname = "vmhba2" /device/00000:004:00.3/vmkname = "vmnic7" /device/00000:011:00.0/vmkname = "vmnic8" /device/00000:011:00.0/vendor = "8086" /device/00000:011:00.0/device = "1528" /device/00000:011:00.0/owner = "vmkernel" - /etc/vmware/esx.conf 33/499 6% |
Save the file.
Reboot the host.
In the VMware ESXi GUI, navigate to Host > Manage.
Select the Hardware tab.
From the PCI Devices, select the SR-IOV card.
Caption | ||||
---|---|---|---|---|
| ||||
Click Configure SR-IOV.
The window to configure the SR-IOV card is displayed.
For the option Enabled, select Yes and set the number of virtual functions.
Caption | ||||
---|---|---|---|---|
| ||||
Click Save.
Configure the other SR-IOV card. Repeat the steps from 4 to 6.
Reboot the host by clicking Reboot host.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||
---|---|---|---|---|
| ||||
Click Reboot.
The VMware ESXi login window is displayed with the message "The host is rebooting...".
Caption | ||||
---|---|---|---|---|
| ||||
Once the virtual function is created, the SR-IOV cards and the Passthru Passthrough for the virtual functions display the status as "Active".
Caption | ||||
---|---|---|---|---|
| ||||
Perform the following steps:
Navigate to Networking. From the Port group tab, click the Add port group.
The Add port group window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Perform the following steps:
Navigate to Networking. From the Port group tab, click the Add port group.
The Add port group window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Perform the following steps:
Navigate to Virtual Machines. Click Create / Register VM to create or register a virtual machine. The Select creation type option is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Select the option Create a new virtual machine.
Click Next.
The Select a name and guest OS option is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Click Next.
The Select storage option is displayed.
Select datastore1.
Info | ||
---|---|---|
| ||
Ensure that the datastore has minimum 500 GB or more space. This datastore is required to store all log-related data files. |
Caption | ||||
---|---|---|---|---|
| ||||
Click Next.
The Customize settings option is displayed.
Configure Virtual Hardware from Customize settings:
Setting CPU
When configuring virtual CPUs within the vSphere Web Client, you can configure:
The following table provides the examples of socket determination based on the CPU and Cores per Socket within the vSphere Web Client:
Caption | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||||||||||||||||||
|
Info | ||
---|---|---|
| ||
It is recommended to use 12 cores or above processor (for example, E5-2690v3 or E5-2699v4, and so on). |
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||
|
Setting Memory
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
|
Setting Hard disk 1
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||
|
Setting SCSI Controller
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Setting Network Adapter 1
The Network Adapter 1 is used for provisioning MGMT ports.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Select Add network adapter. The option to create New Network Adapter for HA port is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Click Add other device to continue the configuration on PKT0 and PKT1.
Caption | ||||
---|---|---|---|---|
| ||||
Select the option PCI device from the drop-down list.
Caption | ||||
---|---|---|---|---|
| ||||
Repeat steps g and h to create one more PCI Device.
Caption | ||||
---|---|---|---|---|
| ||||
Click Next. The Ready to complete option is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Once the VMware instance is created, you must install the SBC application.
Perform the following steps:
Click Edit. The Edit Settings window is displayed.
Select CD/DVD Drive 1.
Caption | ||||
---|---|---|---|---|
| ||||
The Datastore browser window is displayed. Browse the ISO image file.
Caption | ||||
---|---|---|---|---|
| ||||
Click Select. The following window is displayed.
Caption | ||||
---|---|---|---|---|
| ||||
Click Power on to power on the VM.
Caption | ||||
---|---|---|---|---|
| ||||
The Sonus SBC Installer window is displayed. Press Enter to boot.
Caption | ||||
---|---|---|---|---|
| ||||
Once the installation completes, you are prompted to enter the login credentials.
Caption | ||||
---|---|---|---|---|
| ||||
Log on to CLI as linuxadmin
. Provide the following IP addresses:
Primary Management IPv4 Address
Primary Management Network Mask
Primary Management Gateway IP Address, you are prompted to use IPv6 address.
n
if you do not want to set IPv6Caption | ||||
---|---|---|---|---|
| ||||