Panel | ||||
---|---|---|---|---|
| ||||
Enables an inband message to be played when a Progress Indicator is provided on the ISDN disconnect message. Valid entries: Yes (inband message is played post-disconnect) or No (inband message is not played). |
Panel | ||||
---|---|---|---|---|
| ||||
When a Disconnect message with PI=1,8 is received from the ISDN, this field enables the SBC to send a 183 with SDP. Valid options: Yes (SBC sends 183 with SDP) or No (does not send 183 with SDP). Default value: No. This field supports the following example scenario:
|
Panel | ||||
---|---|---|---|---|
| ||||
This parameter defines the timeout value for the inband message play time (when Play Inband Message post-disconnect is configured as Yes). Valid range: 1 0 - 300 seconds. Default value: 10 Seconds. This field is displayed only when Play Inband Message post-disconnect is set to Yes. When set to 0, the SBC does not monitor message play time and does not release the channel by itself. |
...