Caption
0Figure
1Global - Signaling - Diam Sig Controls
 

Image Modified 

The following fields are displayed:

Caption
0Table
1Diam Sig Controls Parameters
 

Parameter

 Description

Enable Rf App

This parameter indicates whether Rf is enabled system wide. Based on this parameter, only normal CDR can be stopped. The options are:

  • enabled
  • disabled (default)
Default CCFThis parameter is used as CDF, if CCF is not received in the PCFA. By default, 0.0.0.0 is displayed.
Rf Interim Acc InrvlThis is over written if Accounting-Answer (ACA) has different value. 0 means no interim record is sent. The value ranges from 0 to 180 and the default value is 30.
Generate Failed Event Acr

If this parameter is enabled, no Accounting-Request (ACR) event for failed call can be sent. The options are:

  • enabled
  • disabled (default)
Max ACRetransmissionThis parameter supports maximum number of retransmission of ACR, if SBC does not receive ACA. The value ranges from 0 to 3 and the default value is 0.
Add Sonus Specific AVP

Enable flag to send additional CDR information within Sonus vendor-specific Attribute Value Pairs (AVPs) in Accounting-Request (ACR) messages over the existing Rf Interface.

  • Disabled (default)
  • Enabled
Info

See Rf Interface for AVP details.

Make the required changes and click Save at the right hand bottom of the panel to save the changes made.

...