Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Panel

...

borderColorgreen
bgColortransparent
borderWidth2

...

Back to Table of Contents

Back to CLI Configure Mode

Back to Operations and Maintenance - CLI

In this section:

Table of Contents

Info
iconfalse

Related articles:

 

...

In this section:

...

The Traps object provides:

  • A list of the traps supported by the
    Spacevars
    0series4
    . These traps are created at system initialization time, without CLI control.
  • A means of enabling and disabling specific traps at the
    Spacevars
    0product
    .

You may use this mechanism to disable specific traps while reconfiguring the

Spacevars
0product
, and then re-enabling them once you are finished. For example, you may cause a number of traps to get reported as a result of a maintenance activity such as temporarily detaching cables.Use this object to prevent these traps from appearing on the SNMP network management stations.

For a list of all possible traps, use the show oam traps command.

Info

...

Refer to Alarms

...

Guide for alarm/trap descriptions.

 

Admin

Use this object to enable or disable specific traps.

Command Syntax

Code Block
languagenone
% set oam traps

...

 admin <trap name>

...

	priorityLevel <critical | default | info | major | minor>
	

...

state <disabled | enabled>

...

Command Parameters

...

Caption
0Table
1

...

Admin Parameters
3Admin Parameters

Parameter

...

Description

...

admin

...

N/A

...

<trap name>

...

 

The trap name.

(

...

Refer to Alarms

...

Guide for a complete list of traps and their descriptions.)

priorityLevel

...

The current priority level of the event/trap/alarm.

...

  • critical – Assign the

...

  • Critical priority level to this event/trap/alarm. 
  • default – Use the manufacturer default priority level for this particular event/trap/alarm. 
  • info – Assign the

...

  • Info priority level to this event/trap/alarm. 
  • major – Assign the

...

  • Major priority level to this event/trap/alarm. 
  • minor – Assign the

...

  • Minor priority level to this event/trap/alarm.

state

...

Enable this flag to send messages to all properly registered and authenticated management clients.

  • disabled
  • enabled (

...

  • Default)

...

dspAdmin

DSP Admin

DSP resource usage trap configuration.

...

Command Syntax

Code Block
languagenone
% set oam traps dspAdmin
	callFailureTrap lackdsp
		interval <60-21600 seconds>
		threshold <1-65535>
	dspAvailabilityTrap
		allThreshold <0-100>
		g711PacketThreshold <0-100>
		g726Threshold <0-100>
		g729Threshold <0-100>

Command Parameters

Caption
0Table
1DSP Admin Parameters
3DSP Admin Parameters

Parameter

Description

callFailureTrap lackdsp

Trap configuration for Call Failure due to no DSP. Options are:

  • interval – The time interval, in seconds, for the threshold of call failure due to lack of DSP pad.
    (range: 60-21600 / default = 300).
  • threshold – Number of call failure due to lack of DSP pad threshold. (range: 1-65535 / default = 100).

dspAvailabilityTrap

...

DSP Availability trap threshold configuration. Specify the following parameters:

  • allThreshold – Percentage DSP Availability threshold for all types. (range: 0-100).
  • g711PacketThreshold – Percentage of G.711 Packet type DSP Availability threshold. (range: 0-100).
  • g726Threshold – Percentage of G.726 type DSP Availability threshold. (range: 0-100).
  • g729Threshold – Percentage of G.729 type DSP Availability threshold. (range: 0-100)

...

displaylevel

...

1-64

...

  • .

Command Example

To display the trap information:

Code Block
languagenone
%  show oam traps admin sonusCpNtpDownNotification
state         enabled;
priorityLevel default;

...

Pagebreak