The two BMC Firmware upgrade paths are listed below and identify which file type to use during the upgrade:

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file.
    For example: To upgrade from BMC 02.16.00 to 03.00.00, use "bmc5X00_v3.0.0-R0.rom" file.

    Note

    The ".rom" file is used only to upgrade BMC version from firmware upgrade to 3.x can only be done from version 02.16.00 to 03.00.00. For BMC versions lower or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the standard method first and then use the perform an upgrade to 3.x version using  a ".rom" file to upgrade it to 03.00.00.

  • BMC upgrade from 3.x to 3.xy: Use the "Disc Image File".
    For example: To upgrade from BMC 03.00.00 to 03.0411.00, use "firmware-5XX0-V03.0411.00-R000.img" file.

Upgrade BMC Firmware from 2.x Version

The following procedure describes how to upgrade the BMC firmware from 2.x to 3.x versions (02.16.00 to 03.00.00) using the ".rom" file.

Note

Download the required BMC firmware version to upgrade from Salesforce. To know more on how to download, refer to Downloading the Software from Salesforce.

Note

Use these steps only to upgrade BMC firmware from 02.16.00 to 03.00.00 version.

  1. Log on to the SBC BMC using the

BMC web GUI.
  1. following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC 2.16 Login Screen

    Image Added

     
    The BMC Main screen is displayed. 
    Caption
    0Figure
    1BMC 2.16 Main Screen

    Image Added

  2. Click Remote Control. The Remote Control window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Remote Control screen

    Image Added


  3. Click Power Control in the Options panel. The Power Control and Status window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Power Control screen

    Image Added


  4. Choose Power Off Server - Orderly Shutdown option.

    Note

    The BMC Server must be shutdown prior to performing a firmware upgrade.


    Caption
    0Figure
    1BMC 2.16 BMC Orderly Shutdown

    Image Added

     

  5. Click Perform Action. The BMC Server shuts down.

    Caption
    0Figure
    1BMC 2.16 BMC Shutdown

    Image Added


  6. Click Maintenance tab. The Maintenance window is displayed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window

    Image Added


  7. Click Enter Update Mode. A message appears seeking your permission to proceed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window Confirmation Message

    Image Added


  8. Click OK to proceed. The BMC is now in the Upgrade Mode.

    Caption
    0Figure
    1BMC 2.16 Firmware Update window

    Image Added


  9. Browse and select the firmware file to upload.

    Caption
    0Figure
    1BMC 2.16 Firmware File

    Image Added


  10. Click Upload Firmware. The BMC validates the selected file.
    Once the verification is complete, a message is displayed stating the result of the verification.

    Caption
    0Figure
    1BMC 2.16 Firmware Validation

    Image Added


  11. Click OK to proceed. The existing and the new BMC versions are displayed for validation.

    Note

    The BMC fails to upgrade if:

    - the selected version is same as the existing version.

    - the selected version is older than the existing version.

    Caption
    0Figure
    1BMC 2.16 Firmware Comparison

    Image Added


  12. Click Start Upgrade to initiate the upgrade process.
    A confirmation message appears seeking your permission to proceed with the upgrade.

    Caption
    0Figure
    1BMC 2.16 Upgrade Confirmation message

    Image Added

     

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.
    - If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and restart the upgrade process from step1.
    - If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.


  13. Click OK to proceed. The BMC starts the firmware upgrade process.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process

    Image Added


    Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.
    Caption
    0Figure
    1BMC 2.16 Upgrade Process Complete

    Image Added

  14. Exit the browser. 
  15. Clear the browser cache.
  16. Open a new browsing window to access the BMC GUI again.
  17. Access the same BMC IP address to reach the BMC login window. Observe the changes in the login window.

    In the new BMC version (03.00.00), the login window has some additional browser settings displayed.

    Caption
    0Figure
    1BMC 3.0 New Login Window

    Image Added


  18. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC 3.0 Main Screen

    Image Added


    The look and feel of the new BMC version (03.00.00) is changed. Explore the new BMC GUI at your leisure.

Upgrade BMC Firmware from 3.x Version

The following procedure describes how to upgrade the BMC firmware from 3.x to 3.x versions (for example; from version 03.10.00 to version 03.11.00) using the Disc Image File.

  1. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC Login Screen

    The BMC main screen is displayed.

    Caption
    0Figure
    1SBC BMC Main Screen

  2. Click Firmware Update.

    Caption
    0Figure
    1BMC Firmware Update option


    The Firmware Update screen is displayed.
    Caption
    0Figure
    1BMC Firware Update screen

  3. Click Browse, and from the Open dialog browse to and select firmware-5XX0-V<release>.img firmware image. Refer to the Warning at the start of this page to make sure you have chosen the correct type of file for an upgrade. To determine the exact firmware version, see SBC Release Information for guidance.

    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Selected Firmware file

  4. Click Upload.

    Note

    The firmware image is approximately 26MB 17MB file and takes few minutes to upload based on the network.

    Note

    The BMC fails to upgrade if:

    - the selected version is same as the existing version.

    - the selected version is older than the existing version.


    The selected file is verified and the uploading process starts.

    Caption
    0Figure
    1Uploading Firmware file

  5. Once the file verification is complete, BMC seeks your permission to proceed further with the upgrade. Click Confirm to proceed.

    Note

    This is a service affecting procedure and will power off the host side of SBC.

    Caption
    0Figure
    1Firmware verification and confirmation window


    Once upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.
    - If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and restart the upgrade process from step1.
    - If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.

    Caption
    0Figure
    1Firmware upload status


    Once the update process is complete, a message is displayed stating the same.
    Caption
    0Figure
    1Firmware Update Complete message

  6. Click OK to complete the process.The BMC automatically restarts at this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

Note
titleNote

For HA configuration, refer to Upgrade Flows for guidance.

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Continue to Upgrading SBC Application.