Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Back to Table of Contents

Back to Customer Replaceable Units

Back to SBC 7000 Series CRUs

Panel

In this section:

Table of Contents
maxLevel2

Tooltip
tipUse ESD protective device

Image Modified

Spacevars
0series2
chassis slot 0 contains the Core Server Card (CSC) module which is used for control and data plan processing. The CSC contains two (2) High Availability ports (10G), two (2) Management Ports (10MB/100MB/1G), and Redundant 10G Packet Ports (2 primary + 2 secondary). The CSC product code is SBC-7000-CSC.

Caption
0Figure
1SBC 7000 Core Server Card

Image Modified

Parts and Tools Required

Tooltip
tipESD protective device

Image Modified

The following items are needed to replace a CSC:

  • Electrostatic discharge (ESD) strap
  • Replacement CSC
  • A #2 Phillips-head screwdriver

Include Page
ESD_wriststrap_7K
ESD_wriststrap_7K

Replacing Core Server Card

Note

Safety shield cover must be intact when system is powered on.

To replace a CSC, do the following:

  1. Perform a graceful shutdown of the 
    Spacevars
    0series2
    system through BMC GUI.
  2. Attach an Electrostatic Discharge wrist strap by using the ESD grounding point on the back panel of the chassis (see Connecting Electrostatic Discharge Wrist Strap on SBC 7000 for details).
  3. Remove all the existing connections from all the ports.
  4. Unscrew the thumb screws using #2 Phillips-head screwdriver, open release levers on each side, and pull the CSC module out.

    Caption
    0Figure
    1SBC 7000 Core Server Card pulled out

    Image Modified

  5. To replace, insert the new module to the correct slot, push the CSC module completely.
  6. Close the release levers.
  7. Tighten the thumb screws using #2 Phillips-head screwdriver.
  8. Re-connect all the ports.
  9. Start the
    Spacevars
    0series2
    system through BMC GUI.

CRU Storage

Tooltip
tipESD protective device

Image Modified

All  

Spacevars
0series2
CRUs are shipped in electrostatic discharge (ESD) bags and must be handled by using appropriate ESD precautions. The storage environment for these CRUs are:

  • Humidity must be less than 95% (non-condensing).
  • Temperature must be between -40C and +70C.

 

Include Page
ESD_footnote
ESD_footnote

Pagebreak