It is important to select the correct firmware file for the existing platform type. The upgrade fails if the platform type mismatches with the selected firmware upgrade file. For example: For SBC 7000 Series platform, the firmware upgrade file should be firmware-7x00-V0x.xx.00-R000.img file.

The following details helps to choose the correct firmware file for an upgrade:

Platform TypeFirmware file
SBC 5000 Series
(5100, 5110, 5200, 5210)

Upgrade from 2.x to 3.x version:

  • bmc5X00_v3.xx.00-R000.rom
  • bmc5X00_v3.xx.00-R000.rom.md5sum

Upgrade from 3.x to 3.y version:

  • firmware-5XX0-V03.yy.00-R000.img
  • firmware-5XX0-V03.yy.00-R000.img.md5

 

SBC 5400

Upgrade from any version to latest version:

  • firmware-5400-V03.xx.00-R000.img
  • firmware-5400-V03.xx.00-R000.img.md5
SBC 7000 Series

Upgrade from any version to latest version:

  • firmware-7x00-V03.xx.00-R000.img
  • firmware-7x00-V03.xx.00-R000.img.md5

Upgrade BMC Firmware for SBC 5400 and SBC 7000 Series

The SBC 5400 and the SBC 7000 Series BMC firmware is upgraded using the standard upgrade method (using the ".rom" file). The standard upgrade method allows you to directly upgrade from any version to the latest BMC version.

Info
titleNote

This method is applicable only to SBC 5400. 

Upgrade Paths for SBC 5000 Series (5100, 5110, 5200, 5210)

The two BMC Firmware upgrade paths are listed below and identify which . Identify the file type to use during the for an upgrade:

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file. 
    For example: To upgrade from BMC 02.16.00 to 03.00.00, use "bmc5X00_v3.0.0-R0.rom" file.

    note
    Info
    titleNote

    The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the standard method first and then perform an upgrade to 3.x version using  a ".rom" file. 

  • BMC upgrade from 3.x to 3.y: Use the "Disc Image File". 
    For example: To upgrade from BMC 03.00.00 to 03.11.00, use "firmware-5XX0-V03.11.00-R000.img" file.

Upgrade BMC Firmware from 2.x Version for SBC 5000 Series (5100, 5110, 5200, 5210)

The following procedure describes how to upgrade the BMC firmware from 2.x to 3.x versions (02.16.00 to 03.00.00) using the ".rom" file.

note
Info
title
Note

Download the required BMC firmware version to upgrade from Salesforce . To know more on how to download, refer prior to continuing. Refer to Downloading the Software from Salesforce for details.

Infonote
titleNote

Use these steps this procedure to only to upgrade BMC firmware from 02.16.00 to 03.00.00 version. 

 

  1. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC 2.16 Login Screen

    Image RemovedImage Added

     
    The BMC Main screen is displayed. 
    Caption
    0Figure
    1BMC 2.16 Main Screen

    Image RemovedImage Added

  2. Click Click Remote Control. The Remote Control window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Remote Control screen

    Image RemovedImage Added


  3. Click Click Power Control in  in the Options panel. The Power Control and Status window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Power Control screen

    Image RemovedImage Added


  4. Choose Choose Power Off Server - Orderly Shutdown option. 

    note
    Info
    titleNote
    The BMC Server server must be shutdown shut down prior to performing a firmware upgrade.

    Caption
    0Figure
    1BMC 2.16 BMC Orderly Shutdown

    Image RemovedImage Added

     

  5. Click Click Perform Action. The BMC Server shuts down. to initiate the shutdown process.

    Caption
    0Figure
    1BMC 2.16 BMC Shutdown

    Image RemovedImage Added


  6. Click Click Maintenance tab tab. The Maintenance window is displayed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window

    Image RemovedImage Added


  7. Click Click Enter Update Mode. A message appears seeking your permission to proceed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window Confirmation Message

    Image RemovedImage Added


  8. Click Click OK to  to proceed. The BMC is now in the Upgrade Mode.

    Caption
    0Figure
    1BMC 2.16 Firmware Update window

    Image RemovedImage Added


  9. Browse and select the firmware file to upload.

    Caption
    0Figure
    1BMC 2.16 Firmware File

    Image RemovedImage Added


  10. Click Click Upload Firmware. The BMC validates the selected file.
    Once the verification is complete, a message is displayed stating the result of the verification.

    Caption
    0Figure
    1BMC 2.16 Firmware Validation

    Image RemovedImage Added


  11. Click Click OK to  to proceed. The  The existing and the new BMC versions are displayed for validation.

    note
    Info
    title
    Note

    The BMC fails to upgrade if:

    - the
    • the selected version is same as the existing version.
    - the
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting a SBC 7000 Series firmware file for an upgrade on SBC 5000 Series platform.

    Caption
    0Figure
    1BMC 2.16 Firmware Comparison

    Image RemovedImage Added


  12. Click Click Start Upgrade to  to initiate the upgrade process.
    A confirmation message appears seeking your permission to proceed with the upgrade.

    Caption
    0Figure
    1BMC 2.16 Upgrade Confirmation message

    Image RemovedImage Added

     

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.- If

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and restart the upgrade process from
    step1
    • step 1.
    - If
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.


  13. Click Click OK to  to proceed. The BMC starts the firmware upgrade process.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process

    Image RemovedImage Added


    Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.
    Caption
    0Figure
    1BMC 2.16 Upgrade Process Complete

    Image RemovedImage Added

  14. Exit the browser. 
  15. Clear the browser cache.
  16. Open a new browsing window to access the BMC GUI again.
  17. Access the same BMC IP address to reach the BMC login window. Observe the changes in the login window.

    In the new BMC version (03.00.00), the login window has some additional browser settings displayed.

    Caption
    0Figure
    1BMC 3.0 New Login Window

    Image RemovedImage Added


  18. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC 3.0 Main Screen

    Image RemovedImage Added


    The look and feel of the new BMC version (03.00.00) is changeddifferent than the previous version. Explore the new BMC GUI at your leisure.

Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series

The following procedure describes how to upgrade the BMC firmware from 3.x to 3.x versions (for example; from version 03.10.00 to version 03.11.00) using the Disc Image File.

  1. Log on to the SBC BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC Login Screen

    Image RemovedImage Added

    The BMC main screen is displayed.

    Caption
    0Figure
    1SBC BMC Main Screen

    Image RemovedImage Added

  2. Click Click Firmware Update.

    Caption
    0Figure
    1BMC Firmware Update option

    Image RemovedImage Added


    The Firmware Update screen is displayed.
    Caption
    0Figure
    1BMC Firware Update screen

    Image RemovedImage Added

  3. Click Click Browse, and from the Open dialog browse to and select firmware-5XX0-V<release>.img firmware  firmware image. Refer to the Warning at the start of this page to make sure you have chosen the correct type of file for an upgrade. To determine the exact firmware version, see refer to SBC Release Information for  for guidance.

    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Selected Firmware file

    Image RemovedImage Added

  4. Click Click Upload.

    note
    Info
    title
    Note

    The firmware image is approximately 17MB file (for SBC 5000 Series) and 24MB (for SBC 5400 and SBC 7000 Series) and takes few minutes to upload based on the network.

    note
    Info
    title
    Note

    The BMC fails to upgrade if:- the

    • the selected version is same as the existing version.
    - the
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting a SBC 7000 Series firmware file for an upgrade on SBC 5000 Series platform.

     

    The selected file is verified and the uploading process starts.

    Caption
    0Figure
    1Uploading Firmware file

    Image RemovedImage Added

  5. Once the file verification is complete, BMC seeks your permission to proceed further with the upgrade. Click Click Confirm to  to proceed.

    Note
    titleCaution

    This is a service affecting procedure and will power off the host side of SBC.

    Caption
    0Figure
    1Firmware verification and confirmation window

    Image RemovedImage Added


    Once upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.- If

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and restart the upgrade process from step1.
    - If
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.

    Caption
    0Figure
    1Firmware upload status

    Image RemovedImage Added


    Once the update process is process is complete, a message is displayed stating the same.
    Caption
    0Figure
    1Firmware Update Complete message

    Image RemovedImage Added

  6. Click Click OK to  to complete the process.The BMC automatically restarts at this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

Noteinfo
titleNote
For HA configuration, refer to Upgrade Flows for guidance.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Continue to Upgrading SBC Application.

Pagebreak