Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH1

...

bgoswami
REV5

...

ksaurabh
REV6

...

mmalaiandi
REV3paramachandra
REV1dajeru

...

 

...

This section describes upgrading the

Spacevars
0product
application in a standalone or HA configuration using the EMA. Beginning with 5.0 release, the Platform Manager is integrated into the EMA and hereafter referred to as EMA Platform Mode. Thus, post 5.0 SBC application upgrades are performed using the EMA.

Info
iconfalse
titleNote

Prior to performing an application upgrade to

...

7.

...

0.0 release, upgrade the SBC Firmware to the latest version on both Active and Standby SBCs for HA pair.

Info
iconfalse
titleNote

Ensure that the following requirements are met prior to performing an upgrade or LSWU to

...

07.

...

00.00R000 release:

  • Ensure the value of the flag, tgMtrgReqMaxBw

...

  • is twice the value of flag tgMtrgBwPerReq

...

Procedure

Warning
titleWarning

 This procedure is service impacting.

Info
iconfalse
titleNote

The BIOS firmware upgrade is not part of SBC application upgrade in

Spacevars
0series2
platforms. Refer to Upgrading SBC 7000 Series Firmware for more information. 

The following procedure describes the 

Spacevars
0series4
application upgrade from version

...

06.

...

02.

...

00R000 to

...

07.

...

00.

...

00R000 release using the EMA (Non-LSWU):

  1. Download the SBC application package from the Salesforce customer portal to your local folder on a PC or remote server. To know more

...

  1. about how to download files, refer to Downloading

...

...

  1. the Ribbon Support Portal.
  2. Validate the SBC md5 checksum using the checksum calculator. See Validating MD5Sum with 'Checksums Calculator' for guidance.

...

  1. LaunchEMA.

  2. Navigate to Monitoring > Dashboard > System and Software Info to verify the software and HA peer status for both active and standby servers.

    Caption
    0Figure
    1System and Software Info Screen for Active Server

    Image Modified

    Caption
    0Figure
    1System and Software Info Screen for Standby Server

    Image Modified

  3. Navigate to Administration > System Administration > File Upload to upload the SBC application package to active and standby SBC servers.

    1. Click File Upload tab.

      Caption
      0Figure
      1File Upload Screen

      Image Modified

    2. Click Add Files to Queue.

    3. Browse the SBC application package files in the File Upload screen and click Open 

      Note

      A new "qcow2" image file is added to the list of upgrade files

...

    1. forupgrade to 6.0.0 R0 and later releases.

      For example: "sbc-

...

    1. V07.

...

    1. 00.00R000-connexip-os_

...

    1. 06.00.00-R000.qcow2".

      Caption
      0Figure
      1Selecting SBC application package

      Image Modified

        

    2. The files are listed in Upload Queue section. Click Upload All Files. The file upload starts.

      Caption
      0Figure
      1Uploading SBC package

      Image Modified

       
       

      Caption
      0Figure
      1Files on SBC

       Image Modified

...

    1.  

    2. Repeat steps "a" through "e" for Standby SBC server.
  1. Stop the application on Active server using Administration > System Administration > Platform Management > Stop SBC Application.

    Caption
    0Figure
    1Stopping SBC Application in Active Server

    Image Modified

  2. The stop application is a service-affecting operation. Click OK to continue the stop operation.

    Caption
    0Figure
    1Confirming Stop SBC Application

    Image Modified

  3. The application is stopped on the active server.

    Caption
    0Figure
    1Application Stopped on Active Server

...

  1.  

  2. Launch the EMA Platform Mode on the Standby server.

    Info
    iconfalse
    titleNote

    Once the Active server (WFDSBC01a) is stopped, the Standby server (WFDSBC01b) automatically becomes active. 

  3. Stop the application on the Standby server using Administration > System Administration > Platform Management > Stop SBC Application.

    Caption
    0Figure
    1Stopping SBC Application on Standby Server

    Image Modified

  4. The stop application is a service-affecting operation. Click OK to continue the stop operation.

    Caption
    0Figure
    1Confirming Stop Application

    Image Modified

  5. The application is stopped on the Standby server.

    Caption
    0Figure
    1Application Stopped on Standby Server

    Image Modified

  6. From the EMA of the initial active server (WFDSBC01a), Navigate to Administration > System Administration > Software Install/Upgrade tab.

  7. Select the SBC Package Name to upgrade, and click Standalone Software Upgrade.

    Info
    iconfalse
    titleNote

    Since, you are performing

...

  1. anon-LSWU upgrade, and both the Active and Standby SBCs are down, it is considered as Standalone Upgrade even for

...

  1. an HA pair. 

    Caption
    0Figure
    1Selecting SBC Package

     Image Modified

     

    The signature file of the SBC package verifies the integrity of the package contents before proceeding with the SBC installation.

    Caption
    0Figure
    1Verifiying Package Integrity

     Image Modified

  2. Click Start Upgrade.

    Caption
    0Figure
    1Selecting Offline Upgrade

     Image Modified

     

    The upgrade process starts on the Active server (WFDSBC01a) and displays the upgrade status on Upgrade Log section.

    Caption
    0Figure
    1Copying Package to Staging and Extract package contents

    Image Modified

    Caption
    0Figure
    1Performing pre-install checks

    Image Modified

    Caption
    0Figure
    1Performing Sonus DB install

    Image Modified

    Info
    iconfalse
    titleNote

    You may lose connectivity to browser session as the server goes for the reboot. 

    Info
    iconfalse
    titleNote

    This process takes approximately 45 minutes to complete on a single server. 

    Warning

    Once the upgrade is successful, clear the browser cache prior to accessing the SBC EMA.

  3. Log on to the EMA using the default credentials.

    Caption
    0Figure
    1Logging On to EMA Platform

    Image Modified

    Caption
    0Figure
    1Logging On to EMA Platform

    Image Modified

  4. Verify the SBC installation status on the Administration > System Administration > Software Install/Upgrade screen.

    Caption
    0Figure
    1Continuing the SBC Upgrade

    Image Modified


    Wait until the SBC upgrade is complete.

    Caption
    0Figure
    1Completing SBC Upgrade

    Image Modified

  5. Verify the SBC application status on the Administration > System Administration > Platform Management screen.

    Caption
    0Figure
    1Verifying Active SBC Status

    Image Modified

    Info
    iconfalse
    titleNote

    Once all the SBC process starts running, continue upgrading the Standby SBC server. 

  6. Follow the step 13 through step 18 to perform an upgrade on the Standby server (WFDSBC01b).

  7. Verify the SBC application status on the Administration > System Administration > Platform Management screen.

    Caption
    0Figure
    1Verifying Standby SBC Status

    Image Modified

  8. Verify the Firmware, ConnexIP OS and SBC application in Monitoring > Dashboard > System and Software Info.

    Caption
    0Figure
    1System and Software Information for Active Server

    Image Modified

    Caption
    0Figure
    1System and Software Information for Standby Server

    Image Modified

  9. Verify the system sync status is in Sync Completed state in All > System > Sync Status.

    Caption
    0Figure
    1System Sync Status

     Image Modified

...

  1.