Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

Excerpt

This section describes viewing and editing TCP Fallback configuration

...

.

To View and Edit TCP Fallback

On the SBC main screen, go

...

to Configuration

...

 > System Provisioning

...

 > Category: SIP Carrier

...

Peering >

...

 Signaling > TCP Fallback.

...

The TCP Fallback

...

 window is displayed.

The TCP Fallback can be checked for each Address Context, for each Zone, for each

...

SIP Trunk Group created or for all the Address Contexts, Zones and

...

SIP Trunk Groups created. Use the drop-down box to select the desired Address Context, Zone and

...

SIP Trunk Group.

...

The Edit TCP Fallback

...

 window is displayed.

Caption
0Figure
1SIP Carrier Peering - Signaling - TCP Fallback

...

Image Added

The following fields are displayed:

Caption
0Table
1

...

SIP Trunk Group - Signaling - TCP Fallback parameters

Parameter

Length/Range

Description

Max MTU Supported Over UDP Control

N/A

 Maximum MTU Size accepted over UDP.

...

  • Disabled (default)

...

  • Enabled

Max MTU Supported Over UDP Value

1-5000Maximum size of the SIP Invite accepted over UDP.

...

Default value is 1300.

Make the required changes and

...

click Save

...

 at the right hand bottom of the panel to save the changes made.

Include Page
TCP_Fallback_Behavior
TCP_Fallback_Behavior

Pagebreak

...