Panel | ||||||
---|---|---|---|---|---|---|
In this section:
|
Sonusprovides replacement units to the customer, and the customer performs the installation for these replacement units provides the following Customer Replaceable Units (CRUs) which are, as the name implies, replaceable by the customer on site.
Caption | ||||
---|---|---|---|---|
| ||||
|
Equipment Requirement | Description |
---|---|
Fan Assembly | Three cooling fan assemblies located behind the front bezel. |
Solid State Drive | Solid State Disk (SSD) storage accessible from rear of the chassis. |
Air Filter | Located within the front bezel assembly for filtering the air drawn into the chassis by the cooling fans. |
SFP/SFP+ | Single or Multi mode fiber transceivers (LC type connector) or copper SFP/SFP+ used for Ethernet connections to Media ports and HA ports. |
Power Supply | Up to two DC or AC power supplies accessible from rear of chassis. |
Bezel | Secures replaceable air filter to front of the chassis and contains the LED status indicators. |
DSP2x | DSP2x Signal Processing Cards (plug-in module with a high capacity DSP card). |
...
Spacevars | ||
---|---|---|
|
The This is the Signal Processing Server (SPS) for for the
Spacevars | ||
---|---|---|
|
The DSP2x cards contain the actual DSP processing resources. The
Spacevars | ||
---|---|---|
|
The DSP2x module includes a Field-Programmable Gate Array (FPGA) that may occasionally require reprogramming. The reprogramming is fully autonomous and occurs during system reboot process. The only noticeable effect to the system is a slight increase to the duration of the system reboot. For each DSP2x installed, expect an additional 1-2 minutes added to the length of a normal reboot process.
...