Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Add_workflow_for_techpubs
AUTH2bscoggins
AUTH1pmohan
REV5ksaurabh
REV6kvenkatraman
REV3hramachandrappa
REV1avalente

Panel

In this section:

Table of Contents
maxLevel4

It is important to select the correct firmware file for the existing platform type. The upgrade fails if the platform type mismatches with the selected firmware upgrade file. For example: For SBC 7000 Series platform, the firmware upgrade file should be firmware-7x00-V0x.xx.00-R000.img file.

To know more on the BMC firmware upgrade process, refer to Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series.

The following details helps to choose the correct firmware file for an upgrade:

Platform TypeFirmware file
SBC 5000 Series
(5100, 5110, 5200, 5210)

Upgrade from 2.x to 3.x version:

  • bmc5X00_v3.xx.00-R000.rom
  • bmc5X00_v3.xx.00-R000.rom.md5sum

Upgrade from 3.x to 3.y version:

  • firmware-5XX0-V03.yy.00-R000.img
  • firmware-5XX0-V03.yy.00-R000.img.md5

 

SBC 5400

Upgrade from any version to latest version:

  • firmware-5400-V03.xx.00-R000.img
  • firmware-5400-V03.xx.00-R000.img.md5
SBC 7000 Series

Upgrade from any version to latest version:

  • firmware-7x00-V03.xx.00-R000.img
  • firmware-7x00-V03.xx.00-R000.img.md5

Upgrade BMC Firmware for SBC 5400 and SBC 7000 Series

The SBC 5400 and the SBC 7000 Series BMC firmware is upgraded using the normal upgrade method (using the ".img" file). The normal upgrade method allows you to directly upgrade from any version to the latest BMC version. Refer to Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series to know the procedure.

Upgrade Paths for SBC 5000 Series (5100, 5110, 5200, 5210)

The two BMC Firmware upgrade paths are listed below. Identify the file type to use for an upgrade:

  • BMC upgrade from 2.x to 3.x: Use the ".rom" file. 
    For example: To upgrade from BMC 02.16.00 to 03.00.00, use "bmc5X00_v3.0.0-R0.rom" file.

    Info
    titleNote

    The firmware upgrade to 3.x can only be done from version 02.16.00 or later. If the existing BMC version is older than 02.16.00, upgrade it to 02.16.00 using the standard method ".img" file first and then perform an upgrade to 3.x version using  using a ".rom" file. 

  • BMC upgrade from 3.x to 3.y: Use the ".img" file. 
    For example: To upgrade from BMC 03.00.00 to 03.11.00, use "firmware-5XX0-V03.11.00-R000.img" file.

Upgrade BMC Firmware from 2.x Version for SBC 5000 Series (5100, 5110, 5200, 5210)

The following procedure describes how to upgrade the BMC firmware from 2.x to 3.x versions (
Info
titleNote

 Execute this procedure twice if your existing BMC version is between 02.11.00 to 02.15.00.

For example: If your existing BMC version is 02.11.00, upgrade it to 02.16.00 and perform an another upgrade from version 02.16.00 to 03.xx.00 using the ".rom" file.

If your existing BMC version is older than 02.11.00, contact TAC for upgrade assistance.

The following procedure describes how to upgrade the BMC firmware from 2.x version 00) using the ".rom" file.

Info
titleNote

Download the required BMC firmware version from Salesforce prior to continuing. Refer to Downloading the Software from Salesforce for details.

Info
titleNote

Use this procedure to upgrade BMC firmware from 02.16.00 to 03.00.00 version. 

 

  1. Log on to the SBC BMC using the following credentials:
    Username: <username>
    Password: <default password>GUI.

    Caption
    0Figure
    1BMC 2.16 Login Screen

     
    The BMC Main screen is displayed. 
    Caption
    0Figure
    1BMC 2.16 Main Screen

  2. Click Remote Control. The Remote Control window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Remote Control screen


  3. Click Power Control in the Options panel. The Power Control and Status window is displayed. 

    Caption
    0Figure
    1BMC 2.16 Power Control screen


  4. Choose Power Off Server - Orderly Shutdown option. 

    Info
    titleNote
    The BMC server must be shut down prior to performing a firmware upgrade.

    Caption
    0Figure
    1BMC 2.16 BMC Orderly Shutdown

     

  5. Click Perform Action to initiate the shutdown process.

    Caption
    0Figure
    1BMC 2.16 BMC Shutdown


  6. Click Maintenance tab. The Maintenance window is displayed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window


  7. Click Enter Update Mode. A message appears seeking your permission to proceed.

    Caption
    0Figure
    1BMC 2.16 Maintenance Window Confirmation Message


  8. Click OK to proceed. The BMC is now in the Upgrade Mode.

    Caption
    0Figure
    1BMC 2.16 Firmware Update window


  9. Browse and select the firmware file to upload. The firmware file to upgrade from 2.x to 3.x version should be a ".rom" file. For example: bmc5X00_v3.0.0-R0.rom file.

    Caption
    0Figure
    1BMC 2.16 Firmware File


  10. Click Upload Firmware. The BMC validates the selected file.Once the verification is complete, a message is displayed stating the result of the verification.

    Caption
    0Figure
    1BMC 2.16 Firmware Validation

    Image Removed

    Click OK to proceed. The existing and the new BMC versions are displayed for validation.

    Info
    titleNote

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting a SBC 7000 Series firmware file for an upgrade on SBC 5000 Series platform.


    Once the verification is complete, a message is displayed stating the result of the verification.

    Caption
    0Figure
    1BMC 2.16 Firmware Validation

    Image Added


  11. Click OK to proceed. The existing and the new BMC versions are displayed for validation.

    Caption
    0Figure
    1BMC 2.16 Firmware Comparison


  12. Click Start Upgrade to initiate the upgrade process.
    A confirmation message appears seeking your permission to proceed with the upgrade.

    Caption
    0Figure
    1BMC 2.16 Upgrade Confirmation message

     

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and reboot BMC. The BMC takes approximately 10 minutes to boot. Once the BMC boots up, re-login to BMC GUI and restart the upgrade process from step 1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.


  13. Click OK to proceed. The BMC starts the firmware upgrade process.

    Caption
    0Figure
    1BMC 2.16 Upgrade Process


    Once the upgrade process is complete, the BMC reboots and a message appears requesting you to open a new browser window to access the BMC GUI.
    Caption
    0Figure
    1BMC 2.16 Upgrade Process Complete

  14. Exit the browser. 
  15. Clear the browser cache.
  16. Open a new browsing window to access the BMC GUI again.
  17. Access the same BMC IP address to reach the BMC login window. Observe the changes in the login window.

    In the new BMC version (03.00.00), the login window has some additional browser settings displayed.

    Caption
    0Figure
    1BMC 3.0 New Login Window


  18. Log on to the SBC BMC using the following credentials:
    Username: <username>
    Password: GUI.<default password>

    Caption
    0Figure
    1BMC 3.0 Main Screen


    The look and feel of the new BMC version (03.00.00) is different than the previous version. Explore the new BMC GUI at your leisureThere are a few display improvements to the 3.X BMC GUI; it is functionally equivalent to previous versions of the BMC.

Anchor
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series
Upgrade BMC Firmware from 3.x Version for SBC 5400 and SBC 5000/7000 Series

The following procedure describes how to upgrade the BMC firmware from 3.x to 3.x versions (for example; from version 03.10.00 to version 03.11.00) using the Disc Image File".img" file.

  1. Log on to the SBC BMC using the following credentials:
    Username: <username>
    Password: <default password>
    GUI.

    Caption
    0Figure
    1BMC Login Screen

    The BMC main screen is displayed.

    Caption
    0Figure
    1SBC BMC Main Screen

  2. Click Firmware Update.

    Caption
    0Figure
    1BMC Firmware Update option


    The Firmware Update screen is displayed.
    Caption
    0Figure
    1BMC Firware Update screen

  3. Click Browse, and from the Open dialog browse to and select select the firmware image (for example; firmware-5XX0-V<release>-V03.11.00-R000.img firmware image). Refer to the Warning at the start of this page to make sure you have chosen the correct type of file for an upgrade. To  To determine the exact firmware version, refer to SBC Release Information for guidance.

    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Selected Firmware file

  4. Click Upload.

    Info
    titleNote

    The firmware image is approximately 17MB (for SBC 5000 Series) and 24MB (for SBC 5400 and SBC 7000 Series) and takes few minutes to upload based on the network.

    Info
    titleNote

    The BMC fails to upgrade if:

    • the selected version is same as the existing version.
    • the selected version is older than the existing version.
    • the selected firmware image is incorrect for the platform type. For example, selecting a SBC 7000 Series firmware file for an upgrade on SBC 5000 Series platform.

     

    The selected file is verified and the uploading process starts.

    Caption
    0Figure
    1Uploading Firmware file

  5. Once the file verification is complete, BMC seeks your permission to proceed further with the upgrade. Click Confirm to proceed.

    Note
    titleCaution

    This is a service affecting procedure and will power off the host side of SBC.

    Caption
    0Figure
    1Firmware verification and confirmation window


    Once upload starts, the actions performed are displayed in the same window along with the estimated time left to complete the process.

    Warning
    titleWarning

    Once the upgrade process starts, do not close the screen.

    • If the window is closed or connectivity is lost before the upgrade starts, re-login to BMC GUI and restart the upgrade process from step1.
    • If the window is closed or the connectivity is lost during the upgrade process, wait for 20 minutes for the upgrade process to complete and try to access the BMC again. If you fail to gain access, contact the Sonus TAC team for assistance.

    Caption
    0Figure
    1Firmware upload status


    Once the update process is complete, a message is displayed stating the same.
    Caption
    0Figure
    1Firmware Update Complete message

  6. Click OK to complete the process.The BMC automatically restarts at this point.

  7. Close the existing browser window.

  8. Clear the browser cache and log on to the BMC GUI again. The updated BMC version is displayed on the BMC main screen.

  9. Log on to the BMC using the default credentials:
    Username: <username>
    Password: <default password>
    GUI.

     The SBC BMC compels asks you to change the password after a successful upgrade.

    Note

    This change is applicable only when the BMC is upgrade to version 03.13.00 and later versions.

    Caption
    0Figure
    1Change Default Password Window

  10. Click OK to proceed. The User Management window is displayed.

    Note

    You have an option to cancel the action. If cancelled, the password remains the same as the default password and you are allowed to continue to work on BMC. However, the warning message is displayed again on you next login to BMC. This reminder continues till the password is changed. To know more about how to successfully change the SBC BMC password, refer to Changing the BMC Password.

  11. Verify the upgraded version in the BMC main screen.

Info
titleNote
For HA configuration, refer to Upgrade Flows for guidance.
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Continue to Upgrading SBC Application.

Pagebreak