The Re-initialize initializing ASM task restores the ASM to an unconfigured state, replacing all software and settings with the image in the the Updating the ASM Recovery Partition Partition .

This operation is typically useful when a Lync SBA needs to be re-deployed, for disaster recovery, or as a means of clearing all software and configuration. Sometimes, it is also used in conjunction after after Updating the ASM Recovery Partition in  in order to load updated software onto the ASM.

This operation can also be used to run a different type of image on the ASM to achieve another role. The ASM is shipped running Lync SBA 2013running Skype for Business 2015 SBA, with the following four images available on the recovery partitionrecovery partition of the ASM SBA:

  • Lync 2013 SBA Cloud Connector Edition image , which allows use of the ASM as a Cloud Connector Appliance with Microsoft CloudPBX.
  • Lync 2013 SBA image, which allows use of the ASM as a Survivable Branch Appliance for  for Lync 2013.
  • Lync 2010 SBA image, which allows use of the ASM as a Survivable Branch Appliance for  for Lync 2010.

In addition to the image loaded onto the ASM recovery partition by Sonus, visit the Sonus SBC Edge Download Center for other image types:

 

Note

Only the ASM image that is based on a licensed Operating System will appear to be re-initialized in the WebUI. If you are not seeing an image that has been previously loaded into the Recovery partition, see below for how to access Notes and Limitations.

...

Show If
matchall
groupconfluence-users

See Notes and Limitations for additional details.

Performing the re-initialization

...

Warning

This operation is both disruptive (it leaves the ASM unavailable for up to 40 minutes) and destructive (it deletes and replaces all software and configuration on the ASM).

  1. In the WebUI, click the the Tasks tab tab.
  2. In the left navigation pane, under the the Application Solution Module, click click Reinitialize.

    Panel
    borderStylenone

    Caption
    0Figure
    1Reinitialize

  3. Select an image type from the Image Type select list.
  4. Click Click Apply
Note

Upon starting the operation, the ASM will become unavailable for up to 40 minutes. It will not provide progress updates (there is no way to see how far along it is), but the Current Activity Status panel will report when the operation is complete.

...

After successfully re-initializing the ASM, proceed with the following actions:

  1. Upgrading the SBC Communication Service Version
  2. If you plan to re-deploy the ASM as a Lync SBA,
    1. You may skip over the Central Site Tasks in the deployment, and continue with the Branch Site Tasks.
    2. Install the latest Cumulative Updates for Lync SBA