Add_docset_workflow | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | |||||||
---|---|---|---|---|---|---|---|
| |||||||
|
Card | Part Number |
---|---|
T1/E1 | 404-40232 |
Info |
---|
Part numbers are subject to change; these parts cannot be ordered by customers. |
The DSI (T1/E1) Interface card is a TNV1 compliant digital interface card, which in integrated into the Main Board. This card has board-mounted protection circuits for electrical isolation and protection against power crossing, lightning surges and hazardous voltages. The Sonus SBC 1000 accommodates the following:
T1/E1 cards on the SBC 1000 are factory installed and can only be upgraded by Sonus-trained service personnel.
Note |
---|
The DSI (T1/E1) Interface card includes a bypass relay (incoming-PRI-to-outgoing-PRI) that latches in the event of a power loss. Refer to Configuring Powerdown Telephony Passthrough for configuration details. |
span
Warning |
---|
Do not remove the top panel of the Sonus SBC 1000 chassis. Operating the Sonus SBC 1000 system with the top panel removed will cause hardware components to overheat and fail. Unauthorized removal of the top panel will void your product warranty and service agreement. |
Card | Height mm/in. (PCB only) | Width mm/in. (PCB only) | Height mm/in. (Includes Connector overhang) | Width mm/in. (Includes Connector overhang) | Total Weight (lbs) |
---|---|---|---|---|---|
T1/E1 | 140.1/5.52 | 50.0/1.97 | 142.7/5.62 | 50.0/1.97 | 0.1 |
Environmental Parameter | Specification |
---|---|
Operating Environmental Conditions | Temperature: 5º to 40º Celsius |
Storage Environmental Condition | Temperature: -40º to 70º Celsius |
Each T1/E1 port on the Interface connector has an LED to indicate its operational status. The status states are described below:
Color | Status | Description |
---|---|---|
Off | No Signal/LOS | Indicates the port is not connected or connected cable is not providing a signal (Loss of signal). |
Green | Link Up | Indicates the port is operating normally. |
Red | LOF | Indicates the port has a Loss Of Framing (LOF) error. |
The T1/E1 ports are connected to the public network using 4-wire shielded 26 AWG or larger twisted pair telecommunication line cords with RJ-48C connector.