Section | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||
---|---|---|---|---|
| ||||
The scenario in which the configuration template is provided. In this case, select FXO ↔ Skype for Business/Lync. |
...
Section | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Panel | ||||
---|---|---|---|---|
| ||||
Enables/disables FXO Port calibration. FXO Port Calibration function determines the optimum impedance and the local loop type settings and configures each selected port accordingly, which eliminates impedance mismatching. Impedance mismatching results in audible echos on the line and reduced call quality. Correctly matching the line impedance reduces or eliminates the echo. A number of factors influence the line impedance; line types which vary from country to country and vary between geographic regions, as well as the distance between the node and the central office. Options: Yes (FXO port calibration is executed) or No (FXO port calibration is not executed). |
...
This example displays a FXO ↔ Skype for Business/Lync setup.
Section | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|