Part Number

T1/E1

404-40232

...

T1/E1 cards on the SBC 1000 are factory installed and can only be upgraded by Sonus-trained service personnel.

 

Note

The DSI (T1/E1) Interface card includes a bypass relay (incoming-PRI-to-outgoing-PRI) that latches in the event of a power loss. Refer to Configuring Powerdown Telephony Passthrough for configuration details.

Span

 

Warning

Do not remove the top panel of the Sonus SBC 1000 chassis. Operating the Sonus SBC 1000 system with the top panel removed will cause hardware components to overheat and fail. Unauthorized removal of the top panel will void your product warranty and service agreement.

...

The T1/E1 ports are connected to the public network using 4-wire shielded 26 AWG or larger twisted pair telecommunication line cords with RJ-48C or RJ-45 connectorsconnector.

Section
Column
width1%

Column

T1/E1 Connector Pinouts

 

Pin Number

Description

1

Receive Ring

2

Receive Tip

3

no connection

4

Transmit Ring

5

Transmit Tip

6

no connection

7

no connection

8

no connection