Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

Add_workflow_for_techpubs
AUTH2AUTH1
REV5
REV6
REV3REV4
REV1
REV2

 

Anchor
BackToTop
BackToTop
Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2
Back to SBC SWe Lite Installation Guide

Panel

In this section:

Table of Contents
maxLevel4

 

This describes

Spacevars
0product
hardware and software requirements and recommendations.

To install and configure

Spacevars
0product
, make sure the Virtual Machine (VM) host meets the following recommended hardware, server platform and software requirements.

 

Warning

The recommended hardware and software settings are intended to ensure optimum 

Spacevars
0product
stability and performance. If the recommended settings are not used, 
Spacevars
0product
system may not behave as expected.

 

 

Warning
titleNOTE TO REVIEWERS

NOTE TO REVIEWERS: ALL CONTENT FROM THIS POINT ON HAS BEEN BORROWED FROM SBC CORE SWE. PLEASE REVIEW ACCORDINGLY. STRIKETHROUGH TEXT WILL BE DELETED UNLESS INSTRUCTED OTHERWISE.

 

Server Hardware Requirements

The following table lists the server hardware requirements:

Caption
0Table
1Server Hardware Requirements

 

 ConfigurationRequirement
Processor2nd Generation Intel Core or Intel Xeon Processor(Sandy bridge or later)
RAMMinimum 16 GB
Hard DiskMinimum ??? GB
Network Interface Cards (NICs)???

Ports

Number of ports allowed:

  • ??? Management port
  • ??? HA port
  • ??? Media ports
Host OSWindows Server 2012 R2 Standard
HypervisorHyper-V, KVM, ESXi, VMWare ESXi
System Type64-bit architecture and 64-bit OS
Warning

The 

Spacevars
0product2
software only runs on platforms using Intel processors. Platforms using AMD processors are not supported.

 

BIOS Setting Recommendations

Sonus recommends the following BIOS settings for optimum performance:

Caption
0Table
1Recommended BIOS Settings for Optimum Performance
BIOS ParameterRecommended
Setting
Details
Intel VT-x (Virtualization Technology)???For hardware virtualization
Intel VT-d (Directed I/O)???If available
Intel Hyper-Threading??? 
Intel Turbo Boost??? 
CPU power management??? 

 

For example, the BIOS settings are shown below for HP DL 380p Gen8 servers. For BIOS settings of other servers, refer to the respective vendor website.

 

Caption
0Table
1BIOS Setting Recommendations for HP DL380p Gen8 Server
BIOS ParameterRecommended
Setting
Default Value
HP Power Profile Maximum PerformanceBalanced Power and Performance
Thermal ConfigurationMaximum CoolingOptimal Cooling
HW PrefetchersDisabledEnabled
Adjacent Sector PrefetcherDisabledEnabled
Processor Power and Utilization MonitoringDisabledEnabled
Memory Pre-Failure NotificationDisabledEnabled
Memory Refresh Rate1x Refresh2x Refresh
Data Direct I/OEnabledDisabled
SR-IOVEnabledDisabled
Intel® VT-dEnabledDisabled

 

Software Requirements - VMware ESXi

The following are the VMware ESXi and

Spacevars
0product2
software requirements:

VMware ESXi Requirements

Caption
0Table
1VMWare ESXi Requirements
SoftwareVersionTested and Qualified VersionFor More Information
vSphere ESXi 5.1 or above
  • VMware 6.0 tested with VM version 11
  • Customized ESXi images for various server platforms are available on VMware and Hardware platform vendor sites.
    • It ensures that all the required drivers for network and storage controllers are available to run ESXi server.
    • Most of the customized ESXi images comes with customized management software to manage server running ESXi software.
    • Customized ESXi images for HP ProLiant and IBM servers are available at:
vSphere Client5.1 or above VMware Knowledge Base
vCenter Server5.1 or above vCenter Server
Warning

Virtual network interfaces will not come up using VMware ESXi 5.5 Update 3. For more information, refer to 5.0.x Release Notes.

Note

The VMware Standard License will be sufficient for 

Spacevars
0series3
unless the PKT interfaces for 
Spacevars
0series3
needs to be configured in Direct IO Pass-through mode. In that case, the Enterprise Plus version of VMware ESXi software is required.

 

Third-Party References:

 

Sonus Recommendations for Optimum Performance

Following are recommended VMware ESXi and 

Spacevars
0series3
virtual machine (VM) configurations. 

General ESXi Recommendations

Following are recommended VMware ESXi configurations:

  • Plan enough resources (RAM, CPU, NIC ports, hard disk, etc.) for all the virtual machines (VMs) to run on server platform, including resources needed by ESXi itself.
  • Allocate each VM only as much virtual hardware as that VM requires. Provisioning a VM with more resources than it requires can, in some cases, reduce the performance of that VM as well as other virtual machines sharing the same host.
  • Disconnect or disable any physical hardware devices (Floppy devices, Network interfaces, Storage controllers, Optical drives, USB controllers, etc.) under BIOS settings that you will not be using to free up interrupt/CPU resources.
  • Use virtual hardware version 8 and above while creating new VMs (available starting ESXi 5.x). This provides additional capabilities to VMs such as supporting VM with up to 1 TB RAM, up to 32 vCPUs etc.

Anchor
ESXi_Param
ESXi_Param
ESXi Host Configuration Parameters

Use VMware vSphere client to configure the following ESXi host configuration parameters on the Advanced Settings page (see figure below) before installing the

Spacevars
0series3
:

Div
classpdf6pttext
Caption
0Table
1ESXi Advanced Settings

 

ESXi Parameter

ESXi 5.1 SettingsESXi 5.5 SettingsESXi 6.0 Settings

Recommended

Default

Recommended

Default

Recommended

Default

Cpu.CoschedCrossCall

0

1

0

1

0

1

Cpu.CreditAgePeriod

500

3000

1000100010001000

DataMover.HardwareAcceleratedInit

0

1

0

1

0

1

DataMover.HardwareAcceleratedMove

0

1

0

1

0

1

Disk.SchedNumReqOutstanding

256

32

(error)(error)(error)(error)

Irq.BestVcpuRouting

1

0

1

0

1

0

Mem.BalancePeriod

0

15

0

15

(error)

(error)

Mem.SamplePeriod

0

60

0

60

(error)

(error)

Mem.ShareScanGHz

0

4

0

4

0

4

Mem.VMOverheadGrowthLimit

0

4294967295

0

4294967295

0

4294967295

Misc.TimerMaxHardPeriod

2000

100000

2000

100000

2000

100000

Misc.TimerMinHardPeriod

100

100

(error)(error)(error)(error)

Net.AllowPT

1

0

1

0

1

0

Net.MaxNetifRxQueueLen

500

100

500

100

500

100

Net.MaxNetifTxQueueLen

1000

500

1000

500

1000

500

Net.NetTxCompletionWorldlet

0

1

01(error)(error)

Net.NetTxWordlet

0

2

1212

Numa.LTermFairnessInterval

0

5

0

5

0

5

Numa.MonMigEnable

0

1

0

1

0

1

Numa.PageMigEnable

0

1

0

1

0

1

Numa.PreferHT

1

0

1

0

1

0

Numa.RebalancePeriod

60000

2000

60000

2000

60000

2000

Numa.SwapInterval

1

3

1

3

1

3

Numa.SwapLoadEnable

0

1

0

1

0

1

 

 

Caption
0Figure
1ESXi Parameters

 

VM Configuration Recommendations

Caption
0Table
1VM Configuration Recommendations

 

 SettingsRecommended Configuration
vCPU

Minimum 4 vCPUs required. But In case where there are only four physical cores available, you must configure the VM with only 3 vCPUs. Any number of vCPUs may be configured depending upon the call capacity requirements.

  • Keep Resource Allocation setting marked as 'unlimited' with CPU freq. set to "physical processor CPU speed multiplied by number of vCPUs assigned to VM".

 

Note

VMDirectPath mode is only supported for PKT ports for vCPUs >=4.

 vRAM

Keep Resource Allocation setting marked as 'unlimited'. Reserve the memory based on call capacity and configuration requirements. Refer to SBC SWe Performance Metrics for supported call capacities with different configuration limits.

Virtual Hard Disk

Set Hard Disk (virtual) size as 100 GB or more (based on requirements of retaining CDRs, logs, etc. for number of days)

    • Use Thick provisioning (eager zero)
    • Hard disk size cannot be changed once SBC SWe software is installed
vNICs

Set number of virtual NICs as 4 (1-MGMT, 1-HA, 1-PKT0 and 1-PKT1).

  • Use only VMXNET3 driver
  • Always use automatic MAC address assignment option while creating vNICs.
  • Associate each vNIC to separate vSwitches
  • Use ESXi NIC teaming feature to achieve redundancy at physical NIC level.
vSwitch settings
  • Use four different vSwitches for each vNICs on
    Spacevars
    0product
    VM. This ensures various traffic to be physically separated on SBC.
    • Assign 1 physical NIC port (1 Gbps) to each vSwitch if physical NIC redundancy is not needed, otherwise assign 2 physical NIC ports (in active-standby mode using NIC team feature) to each vSwitch.

      Note

      The same physical NIC port cannot be associated with different vSwitches.

  • Use four different virtual networking labels, each with different VLANs or subnets.
  • Always run active and standby
    Spacevars
    0product
    VMs on different physical servers
  • Disable VM logging
Note

Make sure the Processors, ESXi version and VM configuration (vCPUs, vRAMs, Virtual Hard Disk, vNICs, and vSwitch Settings) must be identical for an

Spacevars
0series3
HA pair.

Note

Make sure that the BIOS and ESXi settings and recommendations must not be changed once it is applied on the server.

 

Pagebreak