The following SIP Trunks are supported:

  • Generic SIP Trunk
  • ATATT&T IP Flexible ReachGeneric SIP Trunk
  • Verizon Managed Service
  • KDDI SIP Trunk

Depending on the SIP trunk selected, the specific configuration fields are displayed in the Wizard. These are noted below.

Table of Contents
maxLevel3

Step 1 - Select Scenario

Note

These instructions assume the SBC Easy Config wizard is running. See Running Easy Configuration Wizard.

Select the Application type (SIP ↔ Skype for Business/LyncMicrosoft UC). Enter the scenario configuration details based on your deployment settings. Once completed, click Next to move to Step 2 (or Cancel to return to the main WebUI screen).

Scenario Parameters -  Field Definitions

Section
Column
width600px

Caption
0Figure
1Step 1

Application

Panel
bgColor#FAFAFA
borderStylenone

The scenario in which the configuration template is provided. In this case, select SIP Trunk ↔ Skype for Business/LyncMicrosoft UC.

Scenario Description

Panel
bgColor#FAFAFA
borderStylenone

Enter the name to describe Skype for Business/Lync Microsoft UC setup.

 

Info

This value will be prefixed on all the Sonus SBC 1000/2000 configuration elements created by the Setup Wizard pertaining to this deployment.

Telephone Country

Panel
bgColor#FAFAFA
borderStylenone

The country in which the SIP ↔ Skype for Business/LyncMicrosoft UC setup originates.

Emergency Services

Note

The E911 Elin number from the "CompanyName" field configured in Lync location services is used as the authoritative Call Back number for outgoing E911 calls, and is always the preferred configuration. Specifically, it will take precedence over any Callback Number number configuration in Lync Setup. For more information, see Creating and Modifying Entries to Transformation Tables.

Panel
bgColor#FAFAFA
borderStylenone

Defines the Emergency Services for outgoing numbers. For the purpose of this illustration above, Emergency Services is not selected. Field definitions are defined below.

Options:  ELIN Identifier, E911/E112 or None.

Emergency Callback Number 1

Panel
bgColor#FAFAFA
borderStylenone

Call Back Number in string format. This field is displayed only when ELIN Identifier or E911/E112 is selected from Emergency Services.

Emergency Callback Number 2

Panel
bgColor#FAFAFA
borderStylenone

Second Call Back Number in string format. This field is displayed only when ELIN Identifier or E911/E112 is selected from Emergency Services.

PSAP Number

Panel
bgColor#FAFAFA
borderStylenone

Defines the Public Safety Answering Point Number. Valid entry 1 - 127 characters.

SIP Sessions

Panel
bgColor#FAFAFA
borderStylenone

Number of simultaneous SIP sessions allocated. Valid entry 1 - 960.

SIP Trunk

Panel
bgColor#FAFAFA
borderStylenone

The SIP trunk used for connection to the Skype for Business/Lync Microsoft UC environment. Valid options: Generic SIP Trunk, AT&T IP Flexible Reach, and Verizon Managed Service, and KDDI SIP Trunk.

The SIP Trunk selected determines the field options displayed in Step 2. See See Step 2 - Configure SIP Details for Endpoint.

...

Microsoft UC

Panel
bgColor#FAFAFA
borderStylenone
 Defines the version of Skype for Business LyncMicrosoft UC. Valid options: Skype for Business or Lync 2010/2013.
Noprint

Back to top

Step 2 - Configure SIP Details for Endpoint

Enter the scenario configuration details based on the SIP Trunk selected in Configure SIP Trunk with Skype for Business/LyncMicrosoft UC.  Once completed, click Next to move to Step 3 (or Previous to return to the previous screen).

Generic SIP Trunk - Field Definitions

These fields apply if you selected Generic SIP Trunk in Configure SIP Trunk with Skype for Business/LyncMicrosoft UC.

Section
Column
width600px

Caption
0Figure
1Generic SIP Trunk

Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

The FQDN or IP address of the Session Border Controller service provider.

Protocol (Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server. Valid entry UDP or TCP.

Port Number (Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The SIP Server Port number used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server.

Use Secondary Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

Enables or disables the secondary Session Border Controller service provider configured. 

Secondary Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

Specifies the Secondary Border Element Service provider. Valid entry: IP Address or FQDN. This field is available only when Use Secondary Border Element Server is Enabled.

Protocol (Secondary Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The Protocol used for communicating with the Secondary Border Element Server. Valid entry: UDP or TCP. This field is available only when Use Secondary Border Element Server is Enabled.

Port Number (Secondary Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The Port Number used for sending and receiving messages between Sonus SBC 1000/2000 and the Secondary Border Element server. This field is available only when Use Secondary Border Element Server is Enabled.

Server Pool Host

Panel
bgColor#FAFAFA
borderStylenone

The Pool name of the Lync Server (FQDN).

Protocol (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host. Valid entry: TLS or TCP.

Port Number (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone

The Port Number (via TLS or TCP) used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host.

Noprint

Back to top

AT&T IP Flexible Reach - Field Definitions

These fields apply if you selected AT&T IP Flexible Reach in Configure SIP Trunk with Skype for Business/LyncMicrosoft UC.

Section
Column
width600px

Caption
0Figure
1AT&T IP Flexible Reach

Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

The FQDN or IP address of the Session Border Controller service provider.

Protocol (Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server. Valid entry UDP or TCP.

Port Number  (Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The SIP Server Port number used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server.

Use Secondary Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

Enables or disables the secondary Session Border Controller service provider configured. 

Secondary Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

Specifies the Secondary Border Element Service provider. Valid entry: IP Address or FQDN. This field is available only when Use Secondary Border Element Server is Enabled.

Protocol (Secondary Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The Protocol used for communicating with the Secondary Border Element Server. Valid entry: UDP or TCP. This field is available only when Use Secondary Border Element Server is Enabled.

Port Number (Secondary Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The Port Number is used for sending and receiving messages between Sonus SBC 1000/2000 and the Secondary Border Element server. This field is available only when Use Secondary Border Element Server is Enabled.

AT&T Forking Feature

Panel
bgColor#FAFAFA
borderStylenone

Enables/disables AT&T Forking Feature. Valid option: Yes or No.

AT&T IP Toll Free

Panel
bgColor#FAFAFA
borderStylenone

Enables/disables the AT&T Toll Free option. Valid option: Enabled or Disabled.

IP Toll Free Access Number

Panel
bgColor#FAFAFA
borderStylenone

The Toll Free Access Number to use when the AT&T IP Toll Free option is enabled.

Server Pool Host

Panel
bgColor#FAFAFA
borderStylenone

The Pool name of the Lync Server (FQDN).

Protocol (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol to use for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host. Valid entry: TLS or TCP.

Port Number (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone
The Port Number (via TLS or TCP) used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host.
Noprint

Back to top

Verizon Managed Service - Field Definitions

These fields apply if you selected Verizon Managed Service in Configure SIP Trunk with Skype for Business/LyncMicrosoft UC.

Section
Column
width600px

Caption
0Figure
1Verizon Managed Service

 

Border Element Server

Panel
bgColor#FAFAFA
borderStylenone

The FQDN or IP address of the Session Border Controller service provider.

Protocol (Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol to use for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server. This value is fixed at UDP.

Port Number (Border Element Server)

Panel
bgColor#FAFAFA
borderStylenone

The SIP Server Port number used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server.

Server Pool Host

Panel
bgColor#FAFAFA
borderStylenone

The Pool name of the Skype for Business / Lync Server (FQDN).

Protocol (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host. Valid entry: TLS or TCP.

Port Number (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone

The Port Number (via TLS or TCP) used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host.

Noprint

Back to top

KDDI SIP Trunk - Field Definitions

These fields apply if you selected KDDI SIP Trunk in Configure SIP Trunk with Microsoft UC.

Section
Column
width600px

Caption
0Figure
1KDDI SIP Trunk
3KDDI SIP Trunk

Image Added

SIP Server

Panel
bgColor#FAFAFA
borderStylenone

The FQDN or IP address of the Session Border Controller service provider.

Protocol

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server. Valid entry UDP or TCP.

Port Number

Panel
bgColor#FAFAFA
borderStylenone

The SIP Server Port number used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Border Element Server.

Call Prefix

Panel
bgColor#FAFAFA
borderStylenone

 

Address of Record URI

Panel
bgColor#FAFAFA
borderStylenone

 

Static Host

Panel
bgColor#FAFAFA
borderStylenone

 

Authentication ID

Panel
bgColor#FAFAFA
borderStylenone

 

Password

Panel
bgColor#FAFAFA
borderStylenone

 

Confirm Password

Panel
bgColor#FAFAFA
borderStylenone

 

DNS Server IP

Panel
bgColor#FAFAFA
borderStylenone

 

Domain Name

Panel
bgColor#FAFAFA
borderStylenone

 

Server Pool Host

Panel
bgColor#FAFAFA
borderStylenone

The Pool name of the Lync Server (FQDN).

Protocol

Panel
bgColor#FAFAFA
borderStylenone

The IP protocol used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host. Valid entry: TLS or TCP.

Port Number (Server Pool)

Panel
bgColor#FAFAFA
borderStylenone

The Port Number (via TLS or TCP) used for sending and receiving SIP messages between Sonus SBC 1000/2000 and the Server Pool Host.

Noprint

Back to top

Step 3 - Confirm and Submit Configuration

This step displays a summary of the the configuration items from Step 1 and Step 2. Click Finish (to cancel the configuration, click Cancel).

This example displays a SIP ↔ Skype for Business/Lync Microsoft UC with a Generic KDDI SIP Trunk.

Section
Column
width600px

Caption
0Figure
1Step 3