The 

Spacevars
0product
SCOM Management Pack allows customers in a Microsoft Server Environment to monitor the health of their their 
Spacevars
0product
systems using SCOM.

This page guides you through the import and installation procedure of the the Sonus SCOM Management  Management Pack onto the the Microsoft System Center Operations Manager 2007 R2 tool.

Table of Contents

Info

For detailed information on monitoring of the SCOM pack, see SBC SCOM Object Model and Health Monitoring.

Downloading the Sonus SCOM Management Pack

The Sonus SCOM management pack is available for download from the the Sonus SBC Edge Download Center

  1. From the the Sonus SBC Edge Download Center
    1. For SCOM 2007, download the the SBC1K2K_SCOM.MP file file
    2. For SCOM 2012, download the SBC1K2K_SCOM.MPB file file
  2. Save the Management Pack file in a convenient location on the the SCOM host machine

...

  1. Launch the System Center Operations Manager.
  2. Go to Administration.
  3. In the navigation tree, go to to Management Packs > Import Management Packs....

  4. Select the appropriate downloaded file:

    1. For SCOM 2007, select the the SBC1K2K_SCOM.MP file file
    2. For SCOM 2012, select the SBC1K2K_SCOM.MPB file file

 

Installing the Management Pack

Panel
borderStylenone

Caption
0Figure
1Import Management Pack

Image Modified

 

  1. In the Select Management Packs window, click click Install. 
    You will see the progress indicator scrolling as the file is installed.

    Panel
    borderStylenone

    Caption
    0Figure
    1Install

     

     

  2. When the installation process has finished, click click Close.

 

Verify the Installation

  1. Press Press F5 on  on your keyboard to refresh the list.
  2. Verify that the the Sonus SCOM SCOM Management Pack appears in the list.

    Panel
    borderStylenone

    Caption
    0Figure
    1Verify Installation

...

Spacevars
0product
supports SNMPv2c and the standard port 161 is used. The SCOM Management Pack (MP) is related to the discovery of the SBC by mapping the object identifiers (OID's) to various components in the SCOM object model. Once the Management Pack is downloaded and imported into SCOM, the the SNMP management address has  has to be created in the SBC. 

...

Note

The Sonus SBC Edge SCOM Pack works through SNMP. Refer to Working with SCOMSNMP and Alarms for details.

 

Pagebreak