For more information about grounding requirements for the SBC 1000/2000,

Spacevars
0longproduct
see System Grounding Requirements. For more information the power supply units installed inside the Sonus SBC Edge 1000/2000
Spacevars
0longproduct
chassis, see SBC Power Supplies.

...

 

Multiexcerpt
MultiExcerptNamepower-connections

Provide AC power of nominal 120V/60Hz or 240V/50Hz for the equipment rack or shelf where the SBC is installed. For each line feed supplied to the rack or shelf, a dedicated primary branch circuit protection is required.

Warning

Spacevars
0longproduct
 equipment SBC Edge 1000/2000 equipment must be provided with dedicated branch circuit protection as a means of disconnecting the (electric) main to ensure the proper operation of and the safety of the persons servicing and operating this equipment. Therefore, the customer must provide an external circuit breaker that conforms to local electrical codes.

Power connections to Sonus SBC Edge 1000/2000 to 

Spacevars
0longproduct
equipment must be provided from branch mains installed by a trained service personnel. For minimum wire requirements, see the tables below.

Anchor
power-wire-gauges
power-wire-gauges

United States and Canada

Requirements

 

Minimum Wire Size

14 AWG

Minimum Voltage Rating

300 V

Insulation

PVC

Conductor

Stranded

Europe

Requirements

 

Minimum Wire Size

1.63 mm

Minimum Voltage Rating

300 V

Insulation

PVC

Conductor

Stranded

 

...

Warning

Use only the AC power cord(s) supplied with the SBC.

Note

Sonus Ribbon SBC 2000 Only: After the IEC power cord is plugged into the power supply module, secure by engaging the retaining clip over the power cord grip.