Add_workflow_for_techpubs AUTH1 bgoswamiUserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c85b00e8, userName='null'} REV5 mshanmugamUserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26cca00892, userName='null'} REV6 hprasadUserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26c749000c, userName='null'} REV3 jmulcockUserResourceIdentifier{userKey=8a00a0c85652e498015669b485df0004, userName='null'} REV1 cjohnUserResourceIdentifier{userKey=8a00a02355cd1c2f0155cd26ccf9091c, userName='null'}
Type: MAJOR
Description | This alarm indicates there is a connection issue with the remote server used for rsyslogthe SBC failed to establish a TCP connection with Rsyslog server. |
Repetition | Five minutes |
Event Codes | sonusAlarmNodeID sonusAlarmLevel sonusAlarmSequenceId sonusAlarmTime sonusAlarmDescription sonusServerIpAddress |
Instance Fields | sonusServerIpAddress |
Action | Check the rsyslog service status on the remote server and if the SBC can communicate to the remote server. |
Impact | Event messages are not written to the remote server. |
Clearing | Automatic; sonusCpSystemRsyslogRemoteServerConnectionRecovered |
...