This field describes the parameters of the Replacement.
To View and Edit Replacement
On SBC main screen, go to All > Profiles > Digit Parameter Handling > DM PM Rule > Sub Rule > URI Parameter Manipulation > User Info Manipulation > Replacement.
Select the desired DM PM Rule from the drop-down list to view its respective Replacement parameters.
The Replacement window is displayed.
Caption |
---|
0 | Figure |
---|
1 | Sub Rule - Uri Parameter Manipulation - User Info Manipulation - Replacement |
---|
|
|
The following fields are displayed:
Caption |
---|
0 | Table |
---|
1 | Replacement Parameters |
---|
|
Parameter | Description |
---|
Type
| Specifies the type of value supported. The options are: Constant Variable No Change
| Character String
| The options are: Calling Number Called Number Pretranslated Redirection Original Called Number Location Redirecting Outpulse Number Billing Number Gn Dialed Digits Gn Destination Gn User Calling Screened Gn User Calling Not Screened Gn Redirecting Terminating Gn Ported Dialed Gn Called Ces Id Gn Addittional Called Gn Addittional Connected Gn Additional Calling Gn Additional Original Called Gn Additional Redirecting Gn Additional Redirection 252 253 254 Two Stage Collected Contractor Number Gn Network Provided Number Presentation Number Called Directory Number Dialed Number Gn Third Party Number Gn Collect Call Number Gn Local Ani Called In Number Calling Name Pai SIP Display Name Pai Tel Display Name SIP From Display Name Cause Of No Id To URI From URI Pai SIP URI Calling URI Called URI None
| Start Character Position
| The values should be between (0-63). | Number of Characters | The values should be between (0-64). | Value | It can be up to 64 characters. |
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.