Specifies the parameters associated with Mfr1Generate.
To View and Edit Mfr1Generate
On SBC main screen, go to Configuration > Profile Management > Category: Digit Profiles >Digit Profiles > Mfr1Generate.
Select the desired Digit Profile from the drop-down list to view its respective Mfr1Generate parameters.
The Mfr1Generate window is displayed.
Caption |
---|
0 | Figure |
---|
1 | Profile Management - Digit Profiles - Mfr1Generate |
---|
|
|
The following fields are displayed:
Caption |
---|
0 | Table |
---|
1 | Dtmf Mfr1Generate Parameters |
---|
|
Parameter | Description |
---|
Power | Digit generation power level in dBm (range: -50 to -3 / default = -7). | Make | Duration (in milliseconds) of generated digits (range: 0-8000 / default = 65). | Break | Silence duration (in milliseconds) between generated digits (range: 0-8000 / default = 65). | Make Kp | Duration (in milliseconds) of generated KP digits. (range: 0-8000 / default = 105). |
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.