Panel | ||||
---|---|---|---|---|
In this section:
|
This section specifies the Privacy parameters for Egress Ip Attributes.
On SBC main screen, go to Configuration > System Provisioning > Category: Trunk Provisioning > Ip Signaling Profile > Egress Ip Attributes > Privacy > Flags. The Flags window is displayed.
On the Flags window, choose the Ip Signaling Profile as DEFAULT_H323 to view the Privacy-Flags parameters for H323 Trunk Group.
Caption | ||||
---|---|---|---|---|
| ||||
There are no Privacy-Flags parameters for DEFAULT_H323 type of Egress Ip Attributes.
On the Flags window, choose the Ip Signaling Profile as DEFAULT_SIP to view the Privacy-Flags for SIP Trunk Group.
Caption | ||||
---|---|---|---|---|
| ||||
The following fields are displayed:
Caption | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.