Use this object to configure H323 Signaling Port for this zone.
Note |
---|
Each signaling port within an Address Context must use a unique IP address. |
Include Page |
---|
| Unique_IP_for_SigPort |
---|
| Unique_IP_for_SigPort |
---|
|
Include Page |
---|
| IP_IGs_ServedBySeperateProcessors |
---|
| IP_IGs_ServedBySeperateProcessors |
---|
|
To View H323Sig Port
On SBC main screen, go to Configuration > System Provisioning > Category: Base Provisioning > Signaling Ports > H323Sig Port. The H323Sig Port window is displayed.
Caption |
---|
0 | Figure |
---|
1 | Signaling Ports - H323Sig Port |
---|
|
|
The H323Sig Port can be checked for each Address Context or for each Zone or for all the Address Contexts and Zones created. Use the drop-down box to select the desired Address Context and Zone.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Main Field |
---|
|
|
To Edit H323Sig Port
To edit any of the H323Sig Ports in the list, click the radio button next to the specific H323Sig Port name.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Highlighted |
---|
|
|
The Edit Selected H323Sig Port window is displayed below.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Edit Window |
---|
|
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.
To Create H323Sig Port
To create a new H323Sig Port, click New H323Sig Port tab on the H323Sig Port List panel.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Fields |
---|
|
|
The Create New H323Sig Port window is displayed.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Create Window |
---|
|
|
The following fields are displayed:
Caption |
---|
|
Parameter | Description |
---|
Index
| Specify the index value. | IP Interface Group Name
| The name of the IP interface group used by this Signaling Port. | H225Ip Address
| The 32-bit IP address used for H225 signaling. Specified in dotted decimal form (for example 128.127.50.224). Default is 0.0.0.0. | Port Number
| The logical port number of the UDP port to use for this connection. This defines the H.225 well known port. Must be 1-5000, default is 1720. | H245Ip Address
| The 32-bit IP address used for H245 signaling. Specified in dotted decimal form (for example 128.127.50.224). Default is 0.0.0.0. This must equal ipaddress1 in the current implementation. | Mode
| The operational state of the H323 signaling service: inService —the signaling port listens for incoming H323 signal link connection requests.outOfService —the signaling port is not available for incoming H323 signal link connection requests and thus cannot be used to create a new gateway signal links to other H323 gateways.
| State
| The administrative state of this H323 signaling port: disabled —Not active.enabled —Active
| Action
| The method by which active calls using this H323 signaling service are processed when MODE goes to out of service: dryup —all calls are allowed to complete until TIMEOUT expires.force —all calls are dropped immediately.
| Dry Up Timeout
| The time (in minutes) to wait for active calls to finish in order to place the H323 signaling service in out of service MODE. Must be 0-1440, default is 0. | DSCP Value
| Differentiated Services Code Point value (0-63). |
|
To Delete H323Sig Port
To delete any of the created H323Sig Port, click the radio button next to the specific H323Sig Port which you want to delete.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Highlighted |
---|
|
|
Click Delete at the end of the highlighted row. A delete confirmation message appears seeking your decision.
Caption |
---|
0 | Figure |
---|
1 | H323Sig Port Delete Confirmation |
---|
|
|