The front Bezel is a Customer Replaceable Unit (CRU). The purpose of the Bezel is to encase the replaceable air filter and to identify the LED status indicators (Power, Status, Active, Alarm, Locator) on the front panel of the chassis, as shown in figure SBC 7000 Series Bezel below. The Bezel product code is SBC-7000-BEZEL.

Caption
0Figure
1SBC 7000 Series Bezel
3SBC 7000 Series Bezel

Parts and Tools Required

Tooltip
tipESD protective device

The following items are needed to install/replace the bezel:

  • Electrostatic discharge (ESD) strap
  • Replacement Bezel (if swapping out the Bezel)

Include Page
ESD_wriststrap_7K
ESD_wriststrap_7K

Removing/Replacing the Bezel

Note

The Bezel is hot-swappable that is, it can be removed without powering down the SBC chassis.

Perform the following procedure to replace the bezel:

  1. Attach an Electrostatic Discharge wrist strap to the rear grounding point on the back panel of the chassis. Follow the instructions in the section Connecting Electrostatic Discharge Wrist Strap on SBC 7000.
  2. The bezel is fixed to the chassis via four ball studs, one in each corner. Place your hands around the top portion of the bezel and gently pull until the ball stud mounts disengage. Once the top side is free, move your hands toward the bottom then pull gently.

     

    Caption
    0Figure
    1Removing the front Bezel

  3. Install the replacement Bezel assembly by aligning the ball stud mounts to the receiving sockets, and then gently pushing the Bezel until it is secured to the chassis.

CRU Storage

Tooltip
tipESD protective device

All

Spacevars
0series2
CRUs are shipped in electrostatic discharge bags and must be handled by using appropriate ESD precautions.

The storage environment for the CRUs are:

  • Humidity must be less than 95% (non-condensing)
  • Temperature must be between -40C and +70C