EMA displays the following alarm tables:

  • Current
  • Cleared

The cleared alarm table displays all the alarms of type "clear" or "manual clear" from the historical alarms table. In addition, EMA also includes extended history by including clearing traps received from the platform.

Note

Each time an alarm is cleared, a trap is also sent. As the EMA stores that trap in its own database table, it effectively allows an extended alarm history.

Alarm management also contains two types of alarms based on the functionality:

  • SET A SET alarm has one or more clear alarms associated with it. A set alarms enables the alarm LED based on priority.

  • CLEAR A clear alarm disabled the alarm led when all alarms of that level are cleared. There are two types of clearing actions.
    • Manual CLEAR. A  manual clear alarm is a set alarm without a clearing alarm. An operator must manually remove the alarm from the alarm screen using CLI/EMA.
    • Automatic CLEAR. An automatic clearing  alarm  associates a clearing alarm to one or more set alarms, and is cleared without any human interference. For example, sonusCpNtpUpNotification clears both  sonusCpNtpDownNotification and sonusCpNtpAllServersOutOfSyncNotification.

 

Note

All alarm types can be manually cleared.

Viewing the Current Alarms

To view the Current Alarms, from the Sonus EMA menu, navigate to Monitoring > Dashboard > Alarms > Current Alarms. The Current Alarms window is displayed.

Caption
0Figure
1Viewing the current alarms

To view the Cleared Alarms, from the Sonus EMA menu, navigate to Monitoring > Dashboard > Alarms > Cleared Alarms. The Cleared Alarms window is displayed.

Caption
0Figure
1Viewing the cleared alarms

For more information on viewing alarms in the EMA, refer to the section Dashboard - Alarms.

Clearing Alarms

To clear a raise or current alarm, navigate to Monitoring > Dashboard > Alarms > Current Alarms.

  1. Select the alarm by clicking the radio button from the table you want to clear.

    Caption
    0Figure
    1Selecting the alarm to be cleared

  2. Click Edit Alarm to edit the selected alarm.

    Caption
    0Figure
    1Edit Alarm window

  3. Select the Cleared radio button.
  4. Click the Save icon. The alarm will be cleared from the Current Alarms table.

For more information, refer to Dashboard - Alarms.

Viewing the Cleared Alarms

To view the cleared alarms, navigate to Monitoring > Dashboard > Alarms > Cleared Alarms.

Caption
0Figure
1Viewing the cleared alarms

For more information on cleared alarms, refer to Dashboard - Alarms.