Use these instructions to configure your SBC(s) with basic network interface information, and to configure SecureLink application to allow Sonus personnel to remotely set up your SBC platform.

SecureLink is a third-party remote access management tool used extensively by Sonus Support team to allow dedicated remote connectivity into Sonus equipment while providing customers with the latest in security and audit capabilities. SecureLink creates an outbound connection to Sonus, and only allows inbound traffic from Sonus (e.g. only Sonus personnel can use this connection).

Caption
0Figure
1Secure Link Architecture (SBC 5000 series example)
3Secure Link Architecture (SBC 5000 series example)

 

Prerequisites

  • SBC server is racked, cabled and powered up.
  • Server names are known (i.e. “XYZSBC1a” and “XYZSBC1b” as an HA pair).

  • BMC, management and DNS IPs are known (use table below).

  • DNS registration code is known (use table below).

  • Router is configured and connected to SBC mgmt. ports.

  • Router can send traffic to public Internet.

  • User obtained from Sonus the unique registration code for each SBC unit.

  • User provided server name(s), mgmt. IP(s), and NTP IP to Sonus.

The following table depicts the information needed to install SecureLink, and is divided into three sections. You will use this information in the subsequent sections below.

  1. BMC Network
  2. Network Mgmt Interfaces
  3. DNS Configuration

Click here to download an example Prerequisites Table in MS Excel.

 

Caption
0Table
1Prerequisites Table
3table
 1) BMC Network2) Network Mgmt Interfaces3) DNS Configuration
Unit AUnit B Unit AUnit BUnit AUnit B
IP Address  Mgmt 0:    
  Mgmt 1:    
Prefix  Mgmt 0:   
  Mgmt 1:  
Default Gateway  Mgmt 0:  Registration Code:Registration Code:
  Mgmt 1:    

 

Pagebreak

Procedure

Referencing the above three configuration details, perform the following steps to install SecureLink for remote access:

Table of Contents
maxLevel3
minLevel3
stylenone

Anchor
1
1
1. Configure BMC For Remote Access

The SBC servers ship pre-configured with IP address 169.254.77.1 to facilitate out of the box access to the BMC web interface. You must configure your PC/laptop IP address to be on this network so that it can communicate with the 

Spacevars
0series5
server.

  1. Connect  your PC/Laptop via an Ethernet cable to the Field Service Port (FSP) at the back of SBC unit as shown in one of the figures below, and power up the SBC (if not already on).

    Caption
    0Figure
    1Connecting PC to Ethernet Port (SBC 5000 series)

    Note

    The SBC 5210 chassis rear view shown above includes four media ports. gthe SBC 51x0 chassis only contains two media ports.

    Caption
    0Figure
    1Connecting PC to Ethernet Port (SBC 7000 series)

     

     

  2. Verify that both link LEDs at the FSP are lit. If only the left LED is lit, your PC/laptop network adapter link speed may be set to 10 Mbps. Check the PC/laptop Device Manager, and if necessary set your PC/laptop link speed to 100 Mbps/Full Duplex.

  3. If your PC/laptop uses DHCP and Automatic Private IP Address setting is enabled (default setting), the PC/laptop will be assigned an IP address in the same subnet as the initial BMC IP; therefore proceed to step 5.  If your PC/laptop does not use DHCP, proceed to the next step to configure a static IP.

  4. From Control Panel, set your PC/Laptop IP address to 169.254.77.2, subnet mask to 255.255.255.0, and default gateway to 169.254.77.1.

    Windows 7 Path: Control Panel > Network and Sharing Center > Local Area Connection > Local Area Connection Properties > Internet Protocol Version 4 (TCP/IPv4) Properties

    Caption
    0Figure
    1Network and Sharing Center

  5. Type the pre-configured IP address 169.254.77.1 in a web browser (Firefox recommended. If using Internet Explorer, you must  manually add "https://169.254.77.1" as a trusted site) to connect to the BMC web interface.

    Note
    If you receive a security certificate warning, ignore the warning and continue to the website.
  6. From login dialog, enter Username “root” and Password “superuser”. The SBC BMC main screen is displayed.

  7. Click Configure tab. The Configuration screen is displayed. > Network.

    Caption
    0Figure
    1Configuration Screen

    From the Options menu, click BMC Network. The BMC Network Settings screen is displayed.

    Caption
    0Figure
    1Configuring BMC Network

  8. Enter the BMC IP Address, Prefix and Default Gateway network settings, then and click Save to save the configuration.
     

  9. Disconnect the laptop from FSP, and then connect the FSP Port to the router. 

  10. Connect a PC to the IP network that can access the BMC IP address. 

  11. Continue to section B to configure network management interfaces.

Pagebreak

Anchor
2
2
2. Configure Network Management Interfaces

Configure primary and secondary management IP interfaces.

  1. Open a browser and enter the new BMC IP address to connect to the BMC web interface.
  2. Login Log on to the BMC using Username as “root” and Password as “superuser”.

    Caption
    0Figure
    1Logging into BMC


    The SBC BMC main screen is displayed similar to below example.

    Caption
    0Figure
    1Configuration Tab

  3. Click the Configuration tab. The Configuration screen is displayed.
    From the Options menu, click  > Platform Management Network. The Platform Management Network Settings screen displays as shown belowis displayed.
  4. Configure the following network settings for both Management Interfaces 0 and 1, and then click Save:
    • IPv4 Address
    • IPv4 Address Prefix
    • IPv4 Default Gateway

      Caption
      0Figure
      1Configuring Management Network

  5. Continue to section C 3 to configure SecureLink.

Pagebreak

Anchor
3
3
3. Configure SecureLink From EMA

  1. Check that port 22 is set to allow access to securelink.sonusnet.com.
  2. From same network as management IPs, open a browser and enter new mgmt. IP.
  3. Login Log on to EMA unit “a” using Username “admin” and Password “Sonus12345”. Upon initial login, you are prompted to change password.
  4. Navigate to Administration to Administration > System Administration and select Secure Link from the navigation panel.

    Caption
    0Figure
    1SecureLink Window

    Image Modified

  5. From the SecureLink window, enter DNS IP Address associated with your network and the assigned Registration Code (obtained from Sonus).

    Caption
    0Figure
    1Entering DNS IP and Registration Code

     Image Modified

  6. Click Enable Gatekeeper Access.

    Caption
    0Figure
    1Enable Gatekeeper Access

    Image Modified

  7. Wait a minute or two for Gatekeeper access field to change to "enabled" before proceeding.

    Caption
    0Figure
    1Enable Gatekeeper Access

    Image Modified

  8. Click Test SecureLink Access to perform Host name lookup and Direct connectivity tests.

    Caption
    0Figure
    1Test SecureLink Access

    Image Modified 

  9. Observe "Passed" indication for both tests. Your SBC is now configured for SecureLink remote access!

    Caption
    0Figure
    1Test SecureLink Access

    Image Modified 

  10. If you have an HA configuration, return to section 1. Configure BMC For Remote Access and repeat all steps in this procedure for the second SBC 5000/7000 series unit. Then continue to the next step. (Be sure to use Unit B’s information from the Prerequisites Table).

  11. Contact your Sonus representative to test remote connectivity to SBC 5000/7000 series platform via SecureLink.

 

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2

Continue to Installing SBC Application