Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Log on to EMS as admin user.
  2. Under Network Mgmnt, click Cluster / VNF Management. The Cluster/VNF Management window is displayed.
  3. Create S-SBC cluster. For more information, refer to Creating an SBC SWe Cluster.

  4. Click Configurations tab.

  5. Click New Configuration. The New Configuration pane is displayed.

    Caption
    0Figure
    1New Configuration

    Image Modified

  6. Click Master Configurator tab.
  7. Select the version of the configuration from the Version drop-down.

  8. Select SBC Configurator instance from the Master Configurator drop-down.
    This node is used to create the configuration. The SBC Configurator nodes are displayed based on the version selected. Only unlocked SBC Configurator nodes are listed.

  9. Enter a name for the configuration in the Configuration Name field. The SBC configuration name contain only letters, numbers, dashes (-), apostrophes ('), underscores (_), colons (:) and spaces.

    Note

    The cluster ID is set as the default name for the first configuration. You can modify the name. The name must be unique.

    The subsequent configurations are named with a combination of cluster name and some unique identifying information. The default name varies based on how the configuration is created.


  10. Click Create.
    A circular progress bar is displayed against the Master Configurator node. It takes around six minutes to load master configuration.

    Caption
    0Figure
    1Configurator Loading


    When the Master Configurator node is loaded, the Open Editor button is displayed next to the Master Configurator node.
    Caption
    0Figure
    1Open Editor

  11. Click Open Editor. The SBC Configuration Manager window is displayed

    Caption
    0Figure
    1SBC Configuration Manager

    Image Modified

  12. Create the basic S-SBC configuration on the SBC configurator. For information on S-SBC configuration, refer to Creating an SBC SWe Cluster.

  13. Click Apply Saved Changes and Close. A circular progress bar is displayed.

    Caption
    0Figure
    1Saving Configuration

    Image Modified
     


    The configuration is saved on the EMS SWe and the following window displays:
    Caption
    0Figure
    1Locked Configurator

    .

  14. Create CDC configuration (Proceed to Configuring CDC using EMS CALEA User Account).

...

  1. In the SBC Configuration Manager window, navigate to Configuration > Intercept > Call Data Channel. The Call Data Channel window is displayed.

    Caption
    0Figure
    1Call Data Channel for S-SBC

    Note

     You can configure the LI using the default Address Context only. 

  2. Select default from Address Context drop-down menu.

    Caption
    0Figure
    1Call Data Channel for M-SBC

  3. Click New Call Data Channel. The Create New Call Data Channel window is displayed.

    Note

    You can configure the LI using the default Address Context only.

  4. Specify the following values:

    1. Name: Type the name of the call data channel.

    2. Intercept Standard: Select packetcable from the drop-down menu.

    3. Vendor ID: Select ss8 from the drop-down menu.

      Caption
      0Figure
      1Create CDC

      Caption
      0Table
      1Call Data Channel Parameters
      3Parameter Details
       ParameterDescription
      NameSpecifies the name of the CDC.
      Intercept StandardSpecifies the intercept standard used.
      Vendor IdSpecifies the vendor of the LI server used.

  5. Click Save. The object is created successfully.

  6. Click OK.

    Caption
    0Figure
    1Call Data Channel List

    Image Modified

     

  7. Click Apply Saved Changes and Close.

  8.  Activate the CDC configuration (Proceed to Activating CDC Configuration for S-SBC).

...