This section describes the method to upgrade the 

Spacevars
0series2
BMC and BIOS firmware. The BMC and BIOS images are bundled into a single firmware package "firmware-7X00-V<release>.img".

Warning

For an SBC HA pair with ePSX installed, perform a manual switchover on the current Active SBC and allow the system to successfully complete the process prior to performing the BMC upgrade to avoid impairments to ePSX database.

 

The following procedure describes how to upgrade the firmware from the BMC web GUI.

  1. Login to the BMC using the following credentials:
    Username: root
    Password: superuser

    Caption
    0Figure
    1BMC Login Screen

     

    The BMC main screen displays.

    Caption
    0Figure
    1BMC Main Screen



  2. Click Firmware Update. The Firmware Update screen displays.

    Caption
    0Figure
    1Firmware Update Screen



  3. Click Browse, and from the Open dialog browse to and select select firmware-7X00-V01.34.00-R000.V<release>.img firmware image. To determine the exact firmware version, see SBC Release Information for guidance.

    The chosen file displays next to the Browse button.

    Caption
    0Figure
    1Browsing Firmware Image

  4. Click Upload. 

    Note

    The firmware image is a 26MB file and takes few minutes to upload based on the network.



  5. Once upload is completed, the Firmware Update screen displays the firmware images and its details.

    Caption
    0Figure
    1Uploading Firmware Image

    Note

     The above screen displays the list of entities, which are updated. If both the Old Version and New Version are same, then the update status displays as "No".

  6. Click Confirm to continue. The upgrade progress bar displays on the screen.

    Note

    This is a service affecting procedure and will power off the host side of SBC.

  7. After the firmware upgrade is completed, the following screen displays. The BMC automatically restarts.

    Caption
    0Figure
    1Completing Firmware Upgrade

    Note

    Once the upgrade completes, BMC and host reboots automatically. Verify that the SBC starts and sync with its peer server before proceeding further.

  8. Close the BMC GUI.

  9. Clear the browser cache and login into the BMC GUI again.

  10. Log on to the BMC GUI again and verify the upgraded version in the BMC main screen.

...