Caption |
---|
0 | Table |
---|
1 | Diam Sig Controls Parameters |
---|
|
Parameter | Description |
---|
Enable Rf App | This parameter indicates whether Rf is enabled system wide. Based on this parameter, only normal CDR can be stopped. The options are: enabled disabled (default)
| Default CCF | This parameter is used as CDF, if CCF is not received in the PCFA. By default, 0.0.0.0 is displayed. | Rf Interim Acc Inrvl | This is over written if Accounting-Answer (ACA) has different value. 0 means no interim record is sent. The value ranges from 0 to 180 and the default value is 30. | Generate Failed Event Acr | If this parameter is enabled, no Accounting-Request (ACR) event for failed call can be sent. The options are: enabled disabled (default)
| Max ACRetransmission | This parameter supports maximum number of retransmission of ACR, if SBC does not receive ACA. The value ranges from 0 to 3 and the default value is 0. | Add Sonus Specific AVP | Enable flag to send additional CDR information within Sonus vendor-specific Attribute Value Pairs (AVPs) in Accounting-Request (ACR) messages over the existing Rf Interface. Disabled (default)Enabled
Available_since |
---|
Type | Available Since |
---|
Release | 5.0.1 |
---|
|
|
|
Make the required changes and click Save at the right hand bottom of the panel to save the changes made.
...