Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Back to Table of Contents

Back to Configuration

Back to Configuration - Profile Management

Back to Profile Management - Service Profiles

Back to Service Profiles - Disconnect Signal Sequence Profile

Noprint
Panel
borderColorgreen
bgColortransparent
borderWidth2
Panel

In this section:

Table of Contents
maxLevel2

A unique signaling sequence in the format "ssp#", where # is an index value (ex. ssp1).

To View Ssp

On SBC main screen, go navigate to Configuration > Profile Management > Category: Service Profiles >Disconnect Signal Sequence Profile > Ssp.

...

Caption
0Figure
1Configuration - Profile Management - Disconnect Signal Sequence Profile - Ssp Main field

The Ssp window is displayed.

Caption
0Figure
1Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp

...

Caption
0Figure
1Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp Highlighted

The Edit Selected Ssp window is displayed below.

You would not be able to edit as the The field is read-only, and cannot be edited.

To Create Ssp

To create a new Ssp, click New Ssp tab on the Ssp List panel.

...

The following fields are displayed:

Include Page
disconnectSignalingSequenceProfile_limitation
disconnectSignalingSequenceProfile_limitation

Caption
0Table
1Disconnect SSP parameters

Parameter

Description

Name

A unique signaling sequence in the format "ssp#", where # is an index value (ex. ssp1)

position

The position in Disconnect SSP at which to execute this step.
This parameter allows you to insert steps into the middle of a Disconnect SSP without needing to renumber the index of the subsequent SSP steps. Positions begin with zero, so to insert a step in front of step 3 in the current Disconnect SSP, you declare a position of 2. (default = 0).

token

This parameter specifies the token, or action to perform.

  • clear – Initiate call clearing procedures on the call. The disconnect reason is an integer specified in param1.
  • delay – Delay further execution of the Disconnect SSP for the interval (in milliseconds) specified in param1.
  • exec – Start execution of the SSP specified in param1.
  • playAnn – Play the announcement specified in param1. The param1 value must match a previously established announcement number see "Announcement Package - CLI" .
  • playTone – Play the tone specified in param1 for the duration specified in param2. The param1 value must match a defined tone type (see "Tone Profile - CLI" . If param2 is "0", the tone plays indefinitely (or until it completes on its own). Execution of the Disconnect SSP is suspended until the tone completes.

param1

A text field used to pass parameter #1 to the Disconnect SSP signaling sequence that is being configured. This parameter is dependent on the Disconnect signaling token used in this signaling sequence.

param2

A text field used to pass parameter #2 to the Disconnect SSP signaling sequence that is being configured. This parameter is dependent on the Disconnect signaling token used in this signaling sequence.

state

The administrative state of this Disconnect SSP. To reconfigure or delete the profile, set to 'disabled'.

  • disabled (default)
  • enabled

 

To Copy Ssp

To copy any of the created Ssp and to make any minor changes, click the radio button next to the specific Ssp to highlight the row.

...

Caption
0Figure
1Profile Management - Service Profiles - Disconnect Signal Sequence Profile - Ssp Fields

The Copy Selected Ssp window is displayed along with the field details which can be edited.

...