The Sonus SBC 2000 allows you to configure the Identification/Status information, Physical Data Layer, and Networking Layer for the Ethernet ports. If you want to change the IP Address, you must configure the associated Logical Interface or use the Modify Ethernet IP task found under the Tasks tab.

To access the Ethernet Ports on the

...

Spacevars
0product
:

  1. In the WebUI, click the Settings tab.
  2. In the left navigation pane, go to Node Interfaces > Ports.

Panel
borderStylenone
Caption
0Figure
1Ethernet Ports - SBC 2000

 Image Modified

Configuring the Ethernet Ports on

...

the 
Spacevars
0product

  1. Click the expand ( Image Modified) icon next to the port you wish to configure.

    Panel
    borderStylenone
    Caption
    0Figure
    1Ethernet

...

  1. Port - Primary

     

    Image Added

    Caption
    0Figure
    1Ethernet Port - Secondary

    eth_port_change_secondary.pngImage Added 

Note

The ASM 2 Ethernet port is for special applications, and cannot be used for VOIP-gateway or SBC functionalities.

 

Identification/Status - Field Definitions

FieldDefinition
Port Alias

...

...

bgColor#FAFAFA
borderStylenone
Specifies an alternative name for the interface; typically configured by the SNMP-based Network Manager.

...

This parameter is unique among all the interfaces known to the SNMP Network Manager. The value cannot have whitespace characters.
Description

...

...

Description for the port or interface. Maximum entry: 64 characters.
Admin State

...

Specifies the administrative state of the port.

 

Physical/Data Layer - Field Definitions

FieldDescription
Configured Speed

...

bgColor#FAFAFA
borderStylenone

Configures auto-negotiation or a specific speed for the Ethernet port. The default value should be changed only when necessary.

  • Auto: When Auto is selected the port speed is automatically negotiated by the Ethernet port and reported in the Negotiated Speed field.
  • 1000/100/10: The specified port speed 1000 Mbps, 100 Mbps, or 10 Mbps is reported in the Negotiated Speed field.

Configured Duplexity

...

...

Specifies auto-negotiation or a specific value for the duplexity of the Ethernet port. Valid entries:  Auto, Full or Half. Default value: Auto. The default value should be changed only when necessary.
Gigabit Timing Mode

...

bgColor#FAFAFA
borderStylenone
Warning

This field should strictly be left as Auto unless interoperability problems are seen with a specific switch.

For example, HP 1920 is a potential example of a switch in which Sonus has seen interoperability problems.

Defines the interface timing mode for the Ethernet port. Valid entries:

Auto

...

: The interface timing mode is negotiated during auto-negotiation (Preferred). Default entry

...

Master

...

: The SBC drives the interface timing

...

Slave

...

: The peer drives the interface timing

WARNING!

This field should strictly be left as Auto unless interoperability problems are seen with a specific switch. For example, HP 1920 is a potential example of a switch in which Sonus has seen interoperability problems.

 

Networking - Field Definitions

FieldDescription
ACL In

...

bgColor#FAFAFA
borderStylenone
Determines the Access Control List (ACL) to be used on this port when filtering incoming packets. For more information about Access Control Lists, see Managing Access Control Lists.
ACL Forward

...

Determines the Access Control List (ACL) to be used when filtering forwarded (i.e. routed) packets received on this port. For more information about Access Control Lists, see Managing Access Control Lists.
Frame Type

...

bgColor#FAFAFA
borderStylenone

Specifies the type of Ethernet frames that can be received on this port.

  • All: When selected, both untagged and tagged Ethernet frames are accepted on this port.
  • Untagged: When selected, only untagged frames are accepted on this port.
  • Tagged: When selected, only tagged frames are accepted on this port, and no default VLAN will be configured.

...

Note: The ASM 1 Ethernet port is limited to Untagged mode only.

Default Untagged VLAN

...

bgColor#FAFAFA
borderStylenone

...

Specifies the default VLAN

...

to which untagged frames will be assigned

...

when

...

they are received on this port.

...

Visible only when Untagged or All is selected from the Frame Type list box.

...

For more information about VLANs, see Creating and Modifying VLANs.

Note:

...

By default, each Ethernet port will be assigned to their own port specific system created VLAN (e.g. Ethernet 1 VLAN). When the port specific VLAN is selected, IP layer communication takes place with its default Logical Interface (e.g. Ethernet 1 IP).

Tagged VLANs

...

bgColor#FAFAFA
borderStylenone

...

Specifies the tagged VLAN(s) of which this Ethernet port is a member. Only user created VLANs can be selected. Visible only when Tagged or All is selected from the Frame Type list box. Since the ASM 1

...

Ethernet port is limited to Untagged mode only, the Tagged VLAN selection

...

is not be present for this port.

...

 

Ethernet Port Redundancy - Field Definitions

FieldValue/RangeDescription
Redundancy

None (0)
MSTP (1)

Failover (2)

(Previously MSTP State).
Redundant PortNone
Ethernet 1
Ethernet 2
Ethernet 3
Ethernet 4
List will reflect platform type and not offering the port currently being configured as redundant port.
Redundancy RolePrimary (0)
Secondary (1)
Read-only field.
Redundancy StateOnline (0)
Backup (1)
Read-only field that indicates which Ethernet port is active.

 

 

 