The Tenor can be used to provide FXS analog capability to the Sonus SBC 2000

Spacevars
0product
 (SBC), allowing for FAX connectivity. In this article, we describe the steps necessary to deploy a Tenor as an analog device in a Sonus SBC 1000/2000 aSBC - Lync SBA topology. The overall configuration comprises three components: the Lync Server, the Tenor, and the Sonus SBC 1000/2000theSBC:

Section
Column
width510px
Table of Contents
maxLevel3
Column

Notes:

In this article, G.711 voice codec is used and CNG Tone Detection is disabled:

When CNG detection is disabled, the Sonus SBC 1000/2000 theSBC lets the Calling fax machine on either side, ISDN or SIP, to send CNG. However, the Sonus SBC 1000/2000 theSBC is actively listening for and detecting the Fax Answer message that the Answering fax machine sends because Fax pass-thru is enabled.

...

Outbound Fax call flow using Lync call control (signaling and media)

Image Modified

Inbound Fax call flow using Lync call control (signaling and media)

Image Modified

Related Information

...

 

Background Color
colorblue
FQDN
 

 

Background Color
colorblue
IP Address
 

 

Background Color
colorblue
Description
 

Background Color
colorblue
uxdemo.net

Background Color
colorblue
134.56.105.30

Background Color
colorblue
LYNC SBA Domain

Background Color
colorblue
rdc.uxdemo.net

Background Color
colorblue
134.56.105.30

Background Color
colorblue
DNS/AD/Ent. Root CA

Background Color
colorblue
sba247.uxdemo.net

Background Color
colorblue
134.56.105.247

Background Color
colorblue
FQDN of Lync SBA Pool

Background Color
colorblue
ux246.uxdemo.net

Background Color
colorblue
134.56.105.246

Background Color
colorblue
FQDN of the Sonus SBC 2000 GW

Background Color
colorblue
Tenor AF

Background Color
colorblue
134.56.105.41

Background Color
colorblue
Analog Device

Background Color
colorblue
Nortel Meridian

Background Color
colorblue
N/A

Background Color
colorblue
ISDN PBX

...

 

Background Color
colorgreen
Meridian Endpoints
 

 

Background Color
colorgreen
Extensions
 

Background Color
colorgreen
PBX Ph1

Background Color
colorgreen
ext: 6228

Background Color
colorgreen
PBX Ph2

Background Color
colorgreen
ext: 6222

Before You Begin

The Sonus SBC 1000/2000 TheSBC SBA must already be configured. If not, configure and deploy the Lync SBA following the instructions in Deploying the SBA (Survivable Branch Appliance).

...

Panel
borderStylenone

Caption
0Figure
1VoIP Routing Configuration

 

  • Enter the Sonus SBC 1000/2000 theSBC 2000 Gateway IP address in the Primary SIP Server IP/Domain Name field and the relevant Port (5060 in this case)

...

Info

Ensure that the codec settings are identical with the matching codec in Sonus SBC 1000/2000inSBC.
Use only G.711U and/or G.711A.

...

Expand
Click here to see the Tenor AF DB file Software Version P108-09-10
Click here to see the Tenor AF DB file Software Version P108-09-10
Code Block
none
none
# /*<-- System Info. Do not overwrite!
# Product: Tenor AF
# IP: 134.56.105.41
# Subnet: 255.255.255.0
# Gateway: 134.56.105.1
# Software: P108-09-10
# Serial Number: A062-208A35
# DB: DB_CMS_M15_A019_V13.0.0_080109
# Updated: WED JUN 22 22:56:23 2011
# -->*/
config
table off
VOIPNetwork 1
SIte 1
TimeServer 1
set UTCOffset 0:00
set PrimaryServerIPAddr 134.56.113.11
set SecondaryServerIPAddr 128.138.140.44
DialPlan 1
set MAXDNlength 30
set MINDNlength 1
set LongDistancePrefix ""
set CarrierPrefixPattern ""
set INTernationaLPrefix[1] ""
set DialPlanCountry 255
UserProgramDialPlan 1
PRIVateNumberingPlan 1
MasterChassis 1
set Type 6
set DBVersion "DB_CMS_M15_A019_V13.0.0_080109"
set SNMPTrapCommunity "trap community"
IVRFileServer 1
SYSLogServer 1
set id "1"
CDRServer 1
set id "1"
CDRServer 2
set id "2"
set CDRServerPort 9003
new ChannelGroup phone
ChannelGroup phone
new ChannelGroup line
ChannelGroup line
NMSServer 1
DNSHosts 1
DNSServer 1
set UseConfiguredDNSServers 1
set PrimaryServerIPAddr 172.16.250.30
set SecondaryServerIPAddr 134.56.112.12
RadiusInfo UserServer
set name "User Authentication Server"
RadiusInfo EndpointServer
set name "Endpoint Authorization Server"
RadiusInfo RoutingServer
set name "External Routing Server"
DOMain 1
set Company "Quintum"
ZOne 1
GateWay 1
set Description "Tenor AF Gateway"
set OutgoingIPRouting 1
set UseRoutingTable 1
VoiceCodec 1
set name ""
set CodecVoiceCoding 9
set CodecPayloadSize 20
set ucVar2 0
VoiceCodec 2
set name ""
set CodecVoiceCoding 8
set CodecPayloadSize 20
set ucVar2 0
CodecProfile default
CASSignalingGroup phone
set id "phone"
set SignalingType 3
set FlashhookSignal 1
set ForwardDisconnectDelay 800
set CallerIDGeneration 1
set RXGain -6
set TXGain 0
CASSignalingGroup line
set id "line"
set ORientation 0
set SignalingType 3
set FlashhookSignal 1
set ForwardDisconnectDelay 500
set CallerIDDetection 1
set RXGain 6
set TXGain 0
SIPSignalingGroup 1
set PrimarySIPServer "172.16.250.246"
set AllowOnlyProxyCalls 0
set SipPstnInterworking 1
set UserAgentHeader "Quintum/1.0.0"
change 1 lp 5060
add 5061 ua 102 pu 2001 ppw 2001 c[1] 2001
add 5062 ua 103 pu 2002 ppw 2002 c[1] 2002
H323SignalingGroup 1
TrunkCircuitRoutingGroup line
set id "line"
set EndOfDialDigit #
LineCircuitRoutingGroup phone
set id "phone"
set EndOfDialDigit #
set CallWaiting 1
set HolD 1
set UnattendedTRansfer 1
set AttendedTRansfer 1
FaxProfile 1
set FaxNominalDelay 200
IPRoutingGroup default
set EndOfDialDigit #
set MediaQOSValue b0
set SignalingQOSValue b0
ToneProfile 1
set id "1"
DNChannelMap 1
add 2001 ua 102
add 2002 ch 2 ua 103
NumberTable default
set id "default"
add 2001 op 2001
add 2002 op 2002
new NumberTable ToSonus SBC 2000ToSBC
NumberTable ToSonus SBC 2000ToSBC
set id "ToSonus SBC 2000ToSBC"
add 1* op 1*
add 2* op 2*
add 6* op 6*
RoutingTable 1
add LCRG-phone ot UA-101 cdnt NT-ToSonusToSBC SBC 2000 dmc cd
GateKeeperParam 1
EndPointAddressDirectory 1
QOSPolicy 1
RouteDirectory 1
StaticRoute 1
set id "1"
table on

ChannelGroup phone
set SignalingGroupAttached CASSignalingGroup-phone
set RoutingGroupAttached LineCircuitRoutingGroup-phone
ChannelGroup line
set SignalingGroupAttached CASSignalingGroup-line
set RoutingGroupAttached TrunkCircuitRoutingGroup-line
CodecProfile default
set VoiceCodecAttached[1] VoiceCodec-1
set VoiceCodecAttached[2] VoiceCodec-2
TrunkCircuitRoutingGroup line
LineCircuitRoutingGroup phone
IPRoutingGroup default
set CodecProfileAttached CodecProfile-default
StaticRoute 1
set IPRoutingGroupAttached IPRoutingGroup-default
# DO NOT TOUCH: Integrity Checked!

...

Requirements and Prerequisites

  • This document assumes that Sonus SBC 1000/2000 thatSBC Lync 2010 wizard was ran prior to the configuration
  • Running the Lync 2010 wizard will ensure SRTP towards Lync is set to Required
  • Media bypass must be enabled in Lync

SIP Registrar Table

  • Browse to Sonus SBC 1000/2000 toSBC 2000 WebUI > Settings Tab > SIP / Local Registrars (in left pane)
  • Click on Add (plus) button and add a SIP Local Registrar Entry as shown below

...

Media List Configuration

  • Browse to Sonus SBC 1000/2000 toSBC 2000 WebUI > Settings Tab > Media List (in left pane)
  • Click on Add (plus) button and add a Media List Entry as shown below

...

Panel
borderStylenone

Caption
0Figure
1Add Media List

 

Translation Table

  • Browse to Sonus SBC 1000/toSBC 2000 2000 WebUI > Settings Tab > Translation (in left pane)
  • Click on Add (plus) button and add a Translation Table with following entry as shown below

...

Signaling Group (uses UDP only)

  • Browse to Sonus SBC 1000/toSBC 2000 2000 WebUI > Settings Tab > Signaling Groups (in left pane)
  • Click on Add SIP SG button and add a SIP Signaling Group for Tenor Device connectivity as shown below

...

 

Call Routing Table

  • Browse to Sonus SBC 1000/toSBC 2000 2000 WebUI > Settings Tab > Call Routing Table (in left pane)
  • Click on SIP to ISDN Call Route Table and hit Add (plus) button to add an entry to route calls to Tenor (for those with 2xxx extension in this example)

...

  • If you are getting comm errors on the Fax machine, check the following resources for solutions:
  • If faxes are failing, check the E1 port counters for slips and frame errors.

    Expand
    Click here to see a screenshot of a *bad* E1 line
    Click here to see a screenshot of a *bad* E1 line
    Panel
    borderStylenone

    Caption
    0Figure
    1Screenshot of E1 Line

     

     

  • The frame errors and the slips counters must notbe increasing. You can check if they are increasing by resetting the counters. If the errors are increasing, the issue could be caused by one of the following:
    • System timing / clocking. Check the clock source (System -> System Timing) - it should be set to Network/T1/E1 port and not System/Free run. If the clock source is set to Network, but the Current Active Clock shows as Free run, click Apply and ensure that Current Active Clock is now set to Primary. This should resolve the clocking issue as long as the error counters do not increase.
    • If the Tenor is not configured to register with the Sonus SBC 1000/2000 theSBC local SIP registrar and the SIP Signaling group in Sonus SBC 1000/2000 inSBC constantly goes down, check the contents of the var_config.cfg file (from Tenor Config Manager -> Tools -> Var_config -> Edit) and delete the line specifying the transport protocol as in P108 it is obsolete.
    • Bad E1 cable. Replace the cable.
    • Faulty RJ45 jacks. Replace the cable or fix the Rj45 jacks.
    • Faulty RJ45 socket. Try configuring a different T1/E1 port. Visually check the pins in the E1/T1 ports for any differences.

Pagebreak